39.4

Backing Up and Loading Configuration File

You can save a copy/backup of the device's current configuration settings as an ini file to a
folder on your computer, using the Configuration File page. The saved file includes only
parameters that were modified and parameters with other than default values. The
Configuration File page also allows you to load an ini file to the device. If the device has
"lost" its configuration, you can restore the device's configuration by loading the previously
saved ini file or by simply loading a newly created ini file.
You can also save the current configuration to a remote server or USB and update
configuration from an external USB hard drive connected to the device's USB port. For
more information, see USB Storage Capabilities on page 601.
# copy cli-script to <URL of TFTP/HTTP/HTTPS server or USB>
For example:
Remote server:
# copy cli-script to tftp://192.168.0.3/config-device1.txt
USB:
# copy cli-script to usb://config-device1.txt
Note:
When loading an ini file using the Configuration File page, parameters not
included in the ini file are reset to default settings.