Technical Data; Spc4000 - Siemens SPC4000 Installation & Configuration Manual

Intrusion
Hide thumbs Also See for SPC4000:
Table of Contents

Advertisement

Technical Data

3
Technical Data
3.1

SPC4000

Mains voltage
Fuse
Power consumption
Auxiliary power (nominal)
Battery
Battery type
Battery capacity
Battery charger
Operating voltage
1)
Current consumption
Number of on-board zones
EOL resistor
Number of on-board open collector
outputs.
Number of on-board relays
2)
Field bus
Interfaces
Tamper contact
Operating temperature
Relative humidity
Housing protection
Colour
Housing protection class
Mounting
Housing material
Housing
Housing can contain up to
Standards
1)
For EN compliance the supplied current needs to be supported by the battery for required stand by time
2)
Max. 400m between devices with cable types IYSTY 2 x 2 x Ø 0,6 mm (min.), UTP cat5 (solid core) or Belden 9829
14
Siemens Building Technologies
Fire Safety & Security Products
230 VAC, +10 to -15 %, 50 Hz
250 mA T
100 mA @ 230 V AC
1)
Max. 750 mA @ 12 VDC
Optional
Sealed cell valve-regulated
Max. 7 AH / 12 V
Max. 24h for 80 % of battery capacity
n.a.
Max. 100 mA @ 12 V DC
8
Dual 4K7 (default), other resistor combinations configurable
1 internal bell (max. 400 mA resistive),
1 external bell (max. 400 mA resistive),
3 general outputs (each max. 400 mA resistive,
supplied via auxiliary output)
1 strobe, 30 V / 1 A (resistive switching current)
X-BUS on RS-485 (307 kb/s)
1 x X-BUS (1 spur),
1 x RS232 (RJ45 ports, for X-10 or external communications),
1 x USB (PC connection for terminal program access),
1 x SPC Fast Programmer
On-board front cabinet spring tamper
+ 2 auxiliary tamper inputs
5 - 40 °C
Max. 90 % (no condensation)
IP30
RAL 9003
Class II Indoor General
Surface, wall mounted
Steel, > 1.2 mm
Metal enclosure
1 additional Expander (size 150 mm x 82 mm)
Designed to meet
EN50131-1:2006 (Grade 2)
TS50131-3:2003 (Grade 2)
EN50131-6:2008 (Grade 2)
09.2008

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents