Starting the System
9.5

Configuring and Using the Portable ACE Profile

9.6

Configuring 868MHz Wireless Fob Devices

9.6.1

Clearing Alerts Using the Wireless FOB Device

42
Siemens Building Technologies
Fire Safety & Security Products
The SPC Keypad can be configured with a proximity card/device reader. Users
whose profiles are configured as such may remotely SET or UNSET the system,
as well as conduct programming, depending on the level of profile. When a
proximity device has been programmed on the Keypad, the user has the ability to
set or unset the system or enter User Programming by presenting the device within
1cm of the receiver area on the keypad.
To program a Portable ACE on the Keypad:
1.
Enter the Engineer Programming code
(default 1111).
2.
Using the up/down arrow keys, scroll to the
USERS option.
3.
Press SELECT.
4.
Select the EDIT option and select the
USER1 from the list.
5.
Scroll to the PACE option and press
SELECT.
6.
Toggle for ENABLE and DISABLE of the
PACE functionality.
The Keypad flashes PRESENT PACE on
the top line display.
7.
Position the PACE fob within 1cm of the
receiver area on the Keypad.
The keypad indicates that the device has
been registered by displaying PACE
CONFIGURED.
To disable a Portable ACE on the system:
1.
Enter the Engineer Programming code
(default 1111).
2.
Using the up/down arrow keys, scroll to the USERS option.
3.
Press SELECT.
4.
Select the EDIT option and select the USER1 from the list.
5.
Scroll to the PACE option and press SELECT.
6.
Toggle to the DISABLED option
The Keypad indicates UPDATED.
Wireless features and devices will be available with a later market package.
Wireless features and devices will be available with a later market package.
...USER...
EXIT
SELECT
...EDIT...
BACK
SELECT
...USER1...
BACK
SELECT
...PACE...
BACK
SELECT
...ENABLED...
BACK
ENTER
PRESENT PACE
BACK
PACE CONFIGURED
BACK