Intrusion Control Panel
SPC4000
Installation&Configuration
Manual
Building Technologies
Fire Safety & Security Products

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SPC4000

  • Page 1 Intrusion Control Panel SPC4000 Installation&Configuration Manual Building Technologies Fire Safety & Security Products...
  • Page 2 Data and design subject to change without notice. / Supply subject to availability. © 2008 Copyright by Siemens Building Technologies We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our prior express written authorization, nor to use it for any purpose other than for which it was delivered to him.
  • Page 3: Table Of Contents

    Installing an External Antenna with Mounting Bracket......34 Keypad User Interface ................35 Keypad Display ..................37 Data entry on the SPC Keypad...............38 8.2.1 Entering Numeric values.................38 8.2.2 Entering Text...................38 8.2.3 Selecting a Programming Option ............38 Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 4 10.4.13 Engineer Access ..................58 10.4.14 Entry Time ....................59 10.4.15 Exit Time ....................59 10.4.16 Fullset Bell....................59 10.4.17 Fullset Strobe ..................59 10.4.18 Final Exit....................59 10.4.19 Tech Delay ....................60 10.4.20 Fail to Set ....................60 Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 5 Setting the System: PARTSET B............87 11.4 Failing to Set the System ................87 11.5 Force Setting the System................87 11.6 Unsetting the System ................88 11.7 Restoring an Alarm Activation (Alert)............88 11.8 Coded Restore ..................89 Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 6 14.1 Commercial Mode Operation ..............106 14.2 Domestic Mode Operation ..............106 14.3 Full and Local Alarms on the SPC ............107 System Examples and Scenarios............108 15.1 When to Use a Common Area ..............108 Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 7 Appendix L: Zone Types ...............122 16.12 Appendix M: Zone Attributes..............123 16.13 Appendix N: Zone Types and Assignable Attributes ......124 16.14 Appendix O: Wiring of Mains Cable to the SPC Controller....126 Keyword index..................127 Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 8 Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 9: Security

    Do not make any changes or modifications to the device unless they are – expressly mentioned in this manual and have been approved by the manufacturer. Use only spare parts and accessories that have been approved by the – manufacturer. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 10: Transport

    Dangerous situation due to false alarm Make sure to notify all relevant parties and authorities providing assistance – before testing the system. To avoid panic, always inform all those present before testing any alarm – devices. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 11: Service And Maintenance

    Type of Risk DANGER Danger of death or severe bodily harm. WARNING Possible danger of death or severe bodily harm. CAUTION Danger of minor bodily injury or property damage IMPORTANT Danger of malfunctions Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 12: Meanings Of The Hazard Symbols

    Security Meanings of the hazard symbols WARNING Warning of a hazard area WARNING Warning of dangerous electrical voltage Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 13: Directives And Standards

    2004/108/EC “Directive of Electromagnetic Compatibility” and 2006/95/EC “Low Voltage Directive”. The EU declaration of conformity is available to the responsible agencies at: Siemens Building Technologies Fire & Security Products GmbH & Co. oHG 76181 Karlsruhe European Directive 2004/108/EC „Electromagnetic Compatibility”...
  • Page 14: Technical Data

    For EN compliance the supplied current needs to be supported by the battery for required stand by time Max. 400m between devices with cable types IYSTY 2 x 2 x Ø 0,6 mm (min.), UTP cat5 (solid core) or Belden 9829 Siemens Building Technologies Fire Safety & Security Products...
  • Page 15: Keypad

    For EN compliance the supplied current needs to be supported by the battery for required stand by time Max. 400m between devices with cable types IYSTY 2 x 2 x Ø 0,6 mm (min.), UTP cat5 (solid core) or Belden 9829 Siemens Building Technologies Fire Safety & Security Products...
  • Page 16: Input / 2 Output Expander

    For EN compliance the supplied current needs to be supported by the battery for required stand by time Max. 400m between devices with cable types IYSTY 2 x 2 x Ø 0,6 mm (min.), UTP cat5 (solid core) or Belden 9829 Siemens Building Technologies Fire Safety & Security Products...
  • Page 17: Output Expander

    Max. 400m between devices with cable types IYSTY 2 x 2 x Ø 0,6 mm (min.), UTP cat5 (solid core) or Belden 9829 Wireless Expander Wireless features and devices will be available with a later market package. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 18: Product Description

    X10 output controller module SPC Pro Power line Bell/strobe Appliance SPC Pro via USB Modem *Wireless features and devices will be available with a later market package. Fig. 1 SPC Overview Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 19: Spc Features

    Product description SPC Features The following features are incorporated into the SPC4000 Controller design: 8 Inputs with configurable wiring - No End Of Line (NEOL), Single End Of Line (SEOL), Dual End Of Line (DEOL) and Anti-masking PIR supervision (MPIR) 6 Outputs –...
  • Page 20: Mounting System Equipment

    Screw the unit to the wall and mark the position of the bottom two screw hole positions with the unit vertically aligned. * Wireless features and devices will be available with a later market package. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 21: Mounting A Keypad

    Wall Mounting Screw Holes Fig. 2 Standard Enclosure Mounting a keypad For mounting please refer to the corresponding Installation Instruction. Mounting an expander For mounting please refer to the corresponding Installation Instruction. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 22: Controller Hardware

    *NOTE: Wireless features and devices will be available with a later market package. Fig. 3 SPC4000 Controller Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 23 750 mA. X-BUS Interface This is the SPC communications bus used to network Expanders together on the system. See Section 7.1 Wiring the X-BUS Interface. SPC4000 supports one communication channel (1A 1B) for manually addressed Expanders only. On-board Outputs Outputs OP4, OP5, and OP6 are 12 V open collector resistive outputs that share a 400 mA current rating with the auxiliary 12 V Output.
  • Page 24: Wiring The System

    The following modules have Branch Expander wiring capability: 8 Input / 2 Output Expander, 8 Output Expander. See Section 7.2 Wiring of Branch Expander for instructions on branch expander wiring. From Previous Expander To Next Expander SPC Controller Fig. 4 Wiring of Expanders Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 25: Spur (Chain) Configuration

    Within the open loop wiring configuration all Expanders/Keypads are fitted with a jumper, as default, allowing termination on the device. Controller Expander Three Expander Two Expander One Fig. 5 Spur (Chain) Configuration Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 26: Star (Multi-Drop) Configuration

    A star configuration is established when multiple Expanders are wired back to the same input channel of the X-BUS on the SPC Controller. See wiring configuration in Fig. 7. SPC Controller 2 - 4 Expanders Fig. 7 Star Configuration Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 27 (i.e. sites with high electric field interference) connect the cable shield to the SH terminals on the SPC Controller and all networked Expanders. Earth the SH terminal on the Controller ONLY. Do NOT earth the SH terminal on any of the Expanders. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 28: Wiring Of Branch Expander

    Expanders except Keypads. Previous Expander Wireless Gateway Expander (NOTE: Wireless features and devices will be available with a later market package.) Next Expander Branch Fig. 9 Wiring of a Branch Expander Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 29: Wiring The Relay Output

    When the relay is activated the Common terminal connection (COM) is switched from the Normally Closed terminal (NC) to the Normally Open terminal (NO). Normally Open terminal (NO) Common terminal connection (COM) Normally Closed terminal (NC) Fig. 10 Standard Wiring Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 30: Wiring The Zone Inputs

    Default Configuration (DEOL 4K7) Input 2 Alarm Anti-masking Tamper EOL IK Fig. 12 Anti-Masking PIR Configuration Anti-Masking is only reported as "Alarm" type to ARC and if area or system is set. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 31 1K6 ↔ 2K5 Open 3K0, <100 Short 2K7 ↔ 14K0 Mask 300 ↔ 3K9 Closed >15K Discon 4K5 ↔ 9K0 Open >10K Discon Shows the Resistance Ranges Associated with each Configuration Tab. 2 Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 32: Wiring An External Sab Bell

    12 V Sounder input. Please consult the installation sheet of the Sounder device for further details on wiring connections. INT - (SPC controller) INT + (SPC controller) Fig. 14 Internal Sounder Wiring (12 V) Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 33: Installing Plug-In Modules

    Wireless Receiver Module Wireless features and devices will be available with a later market package. 7.8.1 Installing a Wireless Receiver Module Wireless features and devices will be available with a later market package. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 34: Installing An External Antenna

    Wireless features and devices will be available with a later market package. 7.8.3 Installing an External Antenna with Mounting Bracket Wireless features and devices will be available with a later market package. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 35: Keypad User Interface

    Leverage Access Tabs: The leverage access tabs provide access to the Keypad back assembly clips. Users can unhinge these clips from the front Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 36 Portable ACE Fob to within 1cm of this area to SET/UNSET the system. Multi-functional Navigation Key: The multi-functional navigation key in combination with the Keypad display provides an interface for programming the system. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 37: Keypad Display

    Continually press this key to scroll through all programming options available on the current menu level. In alphanumeric mode, press this key over an upper case character to change the character to lower case. Siemens Building Technologies Fire Safety & Security Products...
  • Page 38: Data Entry On The Spc Keypad

    To scroll through the list of options available for selection, press the up and down arrow keys To exit from the feature without saving, press BACK To save the selected option, press SAVE or OK Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 39: Starting The System

    Keypad. SPC Pro is a SDK application providing the ability to program configurations on or offline. SPC Pro programming provides additional advanced communication and X10 functionality not found on the Keypad. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 40: Fast Programmer

    RESCAN SELECT Press NEXT for each status as well as for relative Zones. PROGRAMMIMG MODE Start-up settings are complete. NEXT Enter the default programming code (1111) to start configuring the system. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 41: Creating System Users

    Where User Duress feature is enabled, consecutive user codes (i.e. 2906, 2907) are not permitted, as entering this code from the Keypad would activate a user duress event. The Keypad confirms that the new user has been created. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 42: Configuring And Using The Portable Ace Profile

    Wireless features and devices will be available with a later market package. 9.6.1 Clearing Alerts Using the Wireless FOB Device Wireless features and devices will be available with a later market package. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 43: Engineer Programming Via The Keypad

    Configuring Communication Modules The SPC system supports the SPC intell-modems for communications with analogue lines and mobile network interfacing for enhanced communications and connectivity. The SPC system must be configured accordingly. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 44: Configuring A Gsm Or Pstn Modem

    Select ANSWER MODE to enter the manner …ANSWER MODE… the modem answers incoming calls. BACK SELECT Select SMS ENABLE to enable SMS text messages to mobile phones..SMS ENABLED... BACK SELECT Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 45 PIN code be programmed before it is placed in the SIM holder, to ensure that incorrect PINs are not sent to it.All power should be removed (AC Mains and Battery) when loading the SIM card into the SIM holder. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 46: Variables

    OFFLINE TAMPER System Options under the VARIABLES Menu Tab. 4 SYSTEM STATUS VARIABLES TIMERS AREAS XBUS WIRELESS ZONES OUTPUTS COMMUNICATION TEST UTILITIES Location of Variable Menu in Full Engineer Menu Tab. 5 Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 47 Variable Description Default SECURITY GRADE The Security Grade of the SPC4000 Installation is determined by the setting of this variable. For Grade: 2 further details on security grade requirements see [1]. Country: n/a Security Grade: Choose between Engineer, Grade 2, or Grade 3 Security Country: Choose between Ireland, Europe, or UK.
  • Page 48: Security Grade

    [2], [3]. Scroll to the appropriate country setting: IRELAND, EUROPE, or UK and press SAVE. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 49: Application

    Press SELECT. RENAME The option to RENAME displays. BACK SAVE Press SELECT and use the Keypad to enter the preferred name. PARTSET Press ENTER to save new name. BACK ENTER Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 50: Call Arc Mssg

    To enable or disable the Retrigger feature: ...RETRIGGER... Scroll to the RETRIGGER programming option. BACK SELECT Press SELECT. Toggle between ENABLED and DISABLED for ENABLED preferred option. BACK SAVE Press SAVE to update the setting. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 51: Bell On 1St

    To enable or disable the open zones feature: ...OPEN ZONES... Scroll to the OPEN ZONES programming BACK SELECT option. Press SELECT. ENABLED Toggle between ENABLED and DISABLED for BACK SAVE preferred option. Press SAVE to update the setting. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 52: Show State

    To set Restore on Unset: ..RESTORE ON UNSET.. Scroll to the SMS Auth Mode programming BACK SELECT option. Press SELECT. Xxxx Scroll to the desired xxxx settings. BACK SAVE Press SAVE to update the setting. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 53: Offline Tamper

    Press SELECT. XXXXX Scroll to the desired XXXX settings. For more BACK SAVE detail on settings refer to Section 7.4, Wiring the Zone Inputs. Press SAVE to update the setting. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 54: Timers

    System Options under the TIMERS Menu Tab. 7 SYSTEM STATUS VARIABLES TIMERS AREAS XBUS WIRELESS ZONES OUTPUTS COMMUNICATION TEST UTILITIES Tab. 8 Location of TIMERS Menu in the Full Engineer Menu Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 55 Tab. 9 Timers NOTE Default times are dependent upon the Engineer configuration. * The default times denoted may or may not be allowable and is dependent on the configuration by the Engineer. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 56: Ext Bell Time

    ...EXT BELL DELAY... Scroll to the EXT BELL DELAY programming option. BACK SELECT Press SELECT. (0-600) SEC Enter the preferred time (0-600 secs) BACK SAVE Press SAVE to update the setting. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 57: Strobe Time

    To set the dknock delay: ...DKNOCK DELAY... Scroll to the DKNOCK DELAY programming BACK SELECT option. Press SELECT. (0-99) SEC Enter the preferred time (0-99 sec). BACK SAVE Press SAVE to update the setting. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 58: Mains Sig Delay

    ...ENGINEER ACCESS... Scroll to the ENGINEER ACCESS BACK SELECT programming option. Press SELECT. (0-999) MIN Enter the preferred time (0-999 min). BACK SAVE Press SAVE to update the setting. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 59: Entry Time

    To set the final exit time: ...FINAL EXIT... Scroll to the FINAL EXIT programming option. BACK SELECT Press SELECT. Enter the preferred time (1-45 sec). (1-45) SEC Press SAVE to update the setting. BACK SAVE Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 60: Tech Delay

    ...FAIL TO SET... Scroll to the FAIL TO SET programming option. BACK SELECT Press SELECT. Enter the preferred time (1-999 sec). (1-999) SEC Press SAVE to update the setting. BACK SAVE Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 61: Areas

    AREAS programming option. UPDATED An ellipsis (…) on accompanying graphics denotes when there is a choice of menu selection by scrolling. Upon completion of the programming, the Keypad displays UPDATED momentarily. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 62: Add

    Scroll to the DELETE programming option. BACK SELECT Press SELECT. Scroll to area to be deleted and press AREA 1 SELECT. BACK ENTER Confirmation that the area has been deleted is displayed. AREA DELETED Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 63: Edit

    ACCESS TO E/EXIT BACK SAVE E/EXIT TO ALARM ENABLED BACK SELECT BACK SAVE ENABLED LOCAL BACK SAVE BACK SELECT CHIME ENABLED BACK SELECT BACK SAVE COMMON AREA AREA 2 BACK SELECT BACK SELECT Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 64: X-Bus

    Expander. For this reason, devices with no zones, such as 8 Output Expanders should be addressed last. NOTE Automatically-Addressed Expanders are not supported by the SPC4000. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 65 Using the up and down arrow keys, scroll to BACK SELECT the X-BUS programming option. An ellipsis (…) on accompanying graphics denotes when there is a choice of menu selection by scrolling. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 66: X-Bus Programming

    The selected device beeps and the LED flashes allowing Engineer to locate it. ACTIVATING Press BACK to exit the menu. BACK Locate Keypads using the same menus and following the Keypad choice instead of Expander. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 67: Monitor

    SELECT Keypad Backlight: normal, always, off Buzzer Output: active, silent ...EXPANDER 1... Keypad LED: on, off BACK SELECT Areas: (Areas must be enabled in programming: FULL ENGINEER> NAMES VARIABLES) BACK SELECT Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 68: Wireless

    Wireless features and devices will be available with a later market package. 10.7.5 Sensor Type Wireless features and devices will be available with a later market package.. 10.8 Zone Types and Assignable Attributes See Appendix N: Zone Types and Assignable Attributes. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 69: Programming Zones

    Enter the Engineer Programming code FULL ENGINEER (default 1111). EXIT SELECT Press SELECT for FULL ENGINEER programming..ZONES... Using the up and down arrow keys, scroll to BACK SELECT the ZONES programming option. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 70 The number and type of attributes displayed in the Keypad menus for a particular zone vary depending on the type of zone that is selected. See Appendix N: Zone Types and Assignable Attributes. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 71: Outputs

    Area 2 and 3, and Area 2 Ext. Bell is active, then the Area 1 Ext Bell output is also active. Some output types can only indicate system wide events (no specific area events). Please refer to Tab. 16 for further information. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 72 This output turns on if there is a failure to communicate to the central station ¹) This output type can only indicate system wide events (no area specific events). lease refer to the table above for further information. Output Types Tab. 16 Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 73: Programming Outputs

    Using the up and down arrow keys, scroll to EXIT SELECT the OUTPUTS programming option. An ellipsis (…) on accompanying graphics ...OUTPUTS... denotes when there is a choice of menu BACK SELECT selection by scrolling. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 74 BACK SELECT Press BACK to exit the Outputs menu. For the Output test procedure, see Section ...POLARITY... 10.12.4, Output Test. BACK SELECT ...POSITIVE... BACK SELECT ...LOG... BACK SELECT ...ENABLED... BACK SELECT Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 75: Communication

    The SPC system must be configured accordingly. For configuring a GSM or PSTN Modem, refer to Section 10.2.1, Configuring a GSM or PSTN Modem. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 76: Central Station

    Priority: the modem (primary or back-up) to be used to communicate with – the ARC After programming is complete, the option to make a test call to the station is displayed on the Keypad. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 77: Test

    Using the up and down arrow keys, scroll to BACK SELECT the TEST programming option. An ellipsis (…) on accompanying graphics denotes when there is a choice of menu selection by scrolling. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 78: Bell Test

    The status of the zone and its associated resistance value is displayed. Press NEXT to locate the zone (e.g. CONTROLLER 1 = first zone on Controller). Refer to the table below for correlating status information (valid for Dual EOL resistors). Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 79: Output Test

    The Keypad display indicates the current state of the output on the top line. Toggle the output state ON/OFF. Check that the device connected to the selected output changes state accordingly. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 80: Soak Test

    Scroll to the AUDIBLE OPTIONS programming option. Press SELECT. The following options are available: Keypad – – Ext Bell – Int Bell – Press BACK to exit the Audible Options menu. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 81: Utilities

    10.13.1 Sys Software To view the current system software: Scroll to the SYS SOFTWARE programming option. Press SELECT. The software version currently installed on the system is displayed. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 82: Defaults

    Press BACK to exit the SPC Pro menu. 10.14 Isolate Zones or faults on the system can be manually isolated from the Keypad. Isolating a zone removes that zone from the system until the user de-isolates it. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 83: Event Log

    Press SAVE to confirm. NOTE Engineer code may be changed and should be noted accordingly as Siemens is unable to retrieve this new code. Forgotten codes are be remedied only by a factory default of the system, rendering loss of programming.
  • Page 84: Editing

    Phone Number: enter phone number for SMS calls – Reported Events: enable or disable SMS calls for specific events; Alarms, – Confirmed, Fault, Mode Change, Inhibit Isolate, Other Events Press BACK to exit the SMS SETUP menu. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 85: Installer Text

    Press BACK to exit the INSTALLER TEXT menu. NOTE The Installer contact details programmed in these menu options should also be entered on the Keypad pull-down label on completion of the installation. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 86: User Access Via The Keypad

    To select PARTSET A, enter a valid user code, scroll to the PARTSET A option and press SELECT (right soft key). If the alarm fails to set, see Section 11.4, Failing to Set the System. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 87: Setting The System: Partset B

    QUIT: Selecting this option aborts the attempt to set the system and returns the user to User Programming. FORCE: Selecting this option inhibits the open zone and forces the system to set. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 88: Unsetting The System

    QUIT RESTORE or fault condition is either inhibited or Isolated. ALL ALERTS Alarm conditions on the SPC4000 are RESTORED indicated on the Keypad by a flashing yellow Alert LED and by activation of the buzzer. The Keypad displays the location and nature of the alert condition.
  • Page 89: Coded Restore

    Provide 6-digit code to installer. Receive newly generated code from installer. Enter new code at the AUTH CODE prompt. Press SELECT. The message SYSTEM RESTORED displays on the top line of the display. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 90: User Menus Via The Keypad

    Using the up/down arrow keys, scroll to the MENUS option and press SELECT. VIEW INHIBITS? The INHIBIT option is displayed on the BACK SELECT Keypad. Press SELECT. NO INHIBITS The option VIEW INHIBITS? displays. Press SELECT. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 91: Inhibiting A Zone Or Fault

    A list of zones on the system is displayed. BACK SELECT Select the required zone and toggle the setting from NOT ISOLATED to ISOLATED using the up/down arrow keys..ISOLATED... BACK SELECT Press SELECT to save setting. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 92: Setting The Time And Date

    When WALK TEST is selected, users can test the operation of each alarm device by activating the device and checking to hear if an audible beep sounds at the Keypad. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 93: Performing A Walk Test

    08 APR 08 12:30 and all previous events are displayed for ENABLED one second in turn. To view an event from a particular date, enter the date with the numeric keys. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 94: Enabling The Chime Function

    Press SELECT to accept or enter a new USER1 CREATED user code and press SELECT. The Keypad confirms that the new user has been created. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 95: Editing

    Scroll to the USERS> DELETE programming ...DELETE... option. BACK SELECT Press SELECT. A prompt displays, confirming command to ...USER 1... delete. BACK SELECT Press YES to delete the user. ARE YOU SURE? Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 96: Changing A User Code

    Notification of the following events can be sent to users as SMS messages: Alarm Activation Confirmed Alarms Fault and Tamper Arming and Disarming (Mode Change) Inhibit and Isolate All other types of events Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 97: Sms Events

    Press SELECT for ENABLED [Alternatively, BACK SELECT press SELECT for DISABLED.] Press BACK to exit the SMS EVENTS menu. ENABLE NUMBER The keypad displays UPDATED once the BACK SELECT setting has been saved. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 98: Sms Control

    If a function explained herein does not appear on User keypad menus, the user does not have permission for that functionality. Consult with authorised installation Engineer for appropriate rights and settings. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 99: Sms Commands

    If multiple areas are defined on the system, the status of each of the areas is displayed. For each area on the system, the following options are displayed: Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 100: Zones

    Panic: check this box to enable the Keypad Panic Alarm option. A Panic alarm is generated (All bells, strobes activated) if the left and right soft programming keys on the Keypad are pressed simultaneously. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 101: Log

    12.18 SMS The PSC Provides remote access using SMS. Once a modem is installed and the SPC system is configured for SMS Authentication, features include these SMS abilities: Event notification Remote Commands Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 102: Sms Events

    The X-10 state may however be kept by X-10 devices. In any case, after power-up or reset changes of X-10 state can happen as a result of the user entering a keypad shortcut, through trigger transitions, or through external commands. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 103: Using The Fast Programmer

    To access the data on the Fast Programmer from a PC, the drivers for the Fast Programmer must firstly be loaded onto the PC to enable the operating system to recognize the device. Fast Programmer Interface Fig. 18 Fast Programmer Interface Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 104: Connecting The Fast Programmer To The Spc Controller

    Double click the "SPC.exe " install file Installation in progress. A dialog box regarding Windows certification appears. Siemens deems this acceptable to continue. For further queries, please contact network administrator or a Siemens technician. Click Continue Anyway. Installation safely proceeds.
  • Page 105: Configuring With The Fast Programmer

    The panel searches the Fast programmer for a valid firmware file. Once if finds the firmware file ..FAST PROGRAMMER.. it will allow the user to select and upgrade the EXIT SELECT panel. ..FIRMWARE UPGRADE.. BACK SELECT Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 106: Intruder Alarm Functionality

    Area is fully armed, opening of Entry/Exit zone start the Entry timer. If the alarm is not Unset before the Entry timer expires then the alarm is activated. Tab. 27 Alarm Modes Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 107: Full And Local Alarms On The Spc

    (Strobe) and audible (Bell) indication of an intrusion to the premises or building. By default, the first 3 physical outputs on the SPC4000 Controller are assigned to the External Bell, Internal Bell, and External Bell Strobe. When activated, these 3...
  • Page 108: System Examples And Scenarios

    Accounts, and Sales) and starts the exit timer for the front door. SALES: sets ALL areas assigned to the Common Area (Common area, Accounts and Sales); this is because there are no other unarmed sub-areas on the system Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 109 As a rule it is advisable to use common areas in installations that have only one Keypad located at the common access point, i.e. front door access to the entire building. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 110: Appendix

    Allows users to set up the SMS service for sending short text messages to SETUP SMS mobile phones via the PSTN Line GRANT ACCESS Allows users to grant Engineer or Manufacturer access to the system Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 111: Appendix B: Keypad Engineer Menu

    The FULL ENGINEER Menu automatically disables alarms on the system and allows the FULL ENGINEER engineer to program those engineer options that could trigger alarms on the system without doing so. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 112: Appendix C: Keypad Full Engineer Menu

    FULLSET RESISTANCE BELL SMS AUTH FULLSET MODE STROBE PACE AND FINAL EXIT RESTORE ON TECH UNSET DELAY OFFLINE FAIL TO TAMPER *Wireless features will be available with a later market package. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 113: Appendix E: Spc Controller Status Leds

    Writing to Flash ON: system is writing to flash memory OFF: system is not writing to flash memory LED 6 Heartbeat FLASHING: system is functioning normally FLASHING SPC Controller Status LED’s Tab. 28 Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 114 750 mA supply must be subtracted to determine the amount of available power from the Auxiliary power terminals (0 V, 12 V). Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 115 Appendix SPC Controller Battery Auxiliary 12 V Power Terminals Keypad Keypad I/O Expander Fig. 19 Powering Expanders from the Auxiliary Power Terminals Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 116: Appendix G: Calculating The Battery Power Requirements

    SPC Controller for the given standby time. NOTE Only Sealed Cell Valve Regulated Battery Types to be used. For EN compliance the supplied current needs to be supported by the battery for required stand by time. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 117: Appendix H: Domestic And Commercial Mode Default Settings

    ALARM Controller - Zone 5 ALARM ALARM Controller - Zone 6 ALARM FIREX Controller - Zone 7 ALARM FIRE Controller - Zone 8 PANIC PANIC Tab. 31 Domestic and Commercial Mode Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 118: Appendix I: Wiring Of X10 Interface To The Spc Controller

    Close Area System has been Part Set/Armed Fail to Close System/Area Fail to Set due to open zone or Service required etc. Closing Report System has been fully Set /Armed Automatic Closing Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 119 Panic Bypass Panic zone has been Inhibited/Disabled Panic Trouble Restoral Panic Restoral Alarm/Trouble condition on Panic zone has been eliminated (Can be transmitted when System is Unset / Disarmed, or when zone Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 120 RF Tamper Communication Fail Checksum Fault Bell Restored Communication Restoral Battery Missing PSU Trouble PSU Restoral Battery Restoral Communication Trouble Battery Trouble Watchdog reset Service required Service Completed Tab. 32 SIA Codes Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 121: Appendix K: System Variables

    Variable Description Default SECURITY GRADE The Security Grade of the SPC4000 Installation is determined by the setting of this variable. For Grade: 2 further details on security grade requirements see [1]. Country: n/a Security Grade: Choose between Engineer, Grade 2, or Grade 3 Security Country: Choose between Ireland, Europe, or UK.
  • Page 122: Appendix L: Zone Types

    A zone programmed with the x-shunt zone type inhibits the next consecutive zone on the system whenever it is opened. This operation applies for both SET and UNSET modes. As soon as the x-shunt zone type is closed the next zone becomes de-inhibited again. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 123: Appendix M: Zone Attributes

    As soon as the door is closed the Final Exit time will count down to arming the system. Siemens Building Technologies Fire Safety & Security Products...
  • Page 124: Appendix N: Zone Types And Assignable Attributes

    The delay time of the zone will also delay the alarm transmission to the ARC. 16.13 Appendix N: Zone Types and Assignable Attributes The following table shows which attributes are applicable to each zone type: Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 125 E/Exit Ex/Term Fire Firex Line Panic Holdup Tamper Tech Medic Keyarm Unused Shunt X-Shunt Attribute is assignable for this type of alarm. Attribute is not assignable for this type of alarm. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 126: Appendix O: Wiring Of Mains Cable To The Spc Controller

    The mains cable must be an approved type and marked HO5 VV-F or HO5 VVH2- The plastic tie wrap must be flammability rated V-1. Fig. 21 Cable tie connection to metal indent in base of cabinet Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 127: Keyword Index

    External SAB Bell Wiring 30 Plug-in modules Installing 32 Portable ACE 42 Fast Programmer Programming Configuring 106 X-BUS 67 Connecting 104 Programming tools 38 Using 104 Fob devices 42 Clearing alerts 42 Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 128 Wiring 23 User access 87 Zone attributes 124 User menu 111 Zone inputs User menus 91 Wiring 28 User programming Zone Types 69 Adding users 95 Alarm 124 Chime 95 Zones 70 Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 129 Issued by Siemens Building Technologies Fire & Security Products GmbH & Co. oHG © 2008 Copyright by D-76181 Karlsruhe Siemens Building Technologies Data and design subject to change without notice. www.buildingtechnologies.siemens.com/ Supply subject to availability. Document no. A6V10209305 Edition 25.09.2008...