The AdeptThree has an air filter and moisture trap on its inlet air fitting.
The moisture trap should be emptied periodically; see Chapter 4 for
cleaning instructions. If clean, dry air is not available, additional user-
supplied filtering is required. The AdeptThree air connection inlet is a
1/4-inch Industrial Interchange nipple located at the air filter at the base
of the robot.

Electrical

The facility electrical supply must conform with specifications for the
particular system controller, Adept MC or Adept CC. Refer to the
appropriate controller User's Guide for those specifications.

Robot Workcell Free Space

Adequate space must be provided in the design of the working area
(workcell) to allow for freedom of movement of the AdeptThree within
the area specified in Figure 2-11. Additional allowances are required to
accommodate any installed end-of-arm tooling and the calibration
fixture.
Each robot is calibrated at the factory and the calibration data is stored on
the Robot Signature Card (RSC) in the base of the robot. Under certain
conditions the robot may need to be recalibrated, such as the replacement
of the Joint 3 or Joint 4 modules. Recalibration requires that the
calibration fixture be installed on the base of the robot, see Figure 3-1. If
adequate space is not provided in the workcell, the robot will have to be
removed if recalibration is required.

Floor

The floor at the intended installation site must be concrete to a minimum
of 4.0 inches (102 mm) and must comply with all local codes. The floor
should also be level to avoid having to add shims to attain the correct
installation position for the robot.