Mitsubishi Electric M700V Series Programming Manual page 592

Hide thumbs Also See for M700V Series:
Table of Contents

Advertisement

Appendix 1. Program Error
Error No.
P611
No spec: Exponential function
Specification for exponential interpolation is
not available.
P612
Exponential function error
A movement command for exponential
interpolation was issued during mirror image
for facing tool posts.
P700
Illegal command value
Spindle synchronization was commanded to a
spindle that is not connected serially.
P900
No spec: Normal line control
A normal line control command (G40.1,
G41.1, G42.1) was issued when the normal
line control specifications were not provided.
P901
Normal line control axis G92
A coordinate system preset command (G92)
was issued to a normal line control axis during
normal line control.
P902
Normal line control axis error
• The normal line control axis was set to a
linear axis.
• The normal line control axis was set to the
linear type rotary axis II axis.
• The normal line control axis has not been
set.
• The normal line control axis was the same
as the plane selection axis.
P903
Plane chg in Normal line ctrl
The plane selection command (G17, G18,
G19) was issued during normal line control.
P920
No spec: 3D coord conv
There is no specification for 3-dimensional
coordinate conversion.
P921
Illegal G code at 3D coord
A G code command that cannot be performed
was made during 3-dimensional coordinate
conversion modal.
P922
Illegal mode at 3D coord
A 3-dimensional coordinate conversion
command was issued during a modal for
which 3-dimensional coordinate conversion
cannot be performed.
P923
Illegal addr in 3D coord blk
A G code for which G68 to combination could
not be performed was specified for the same
block.
Details
580
Remedy
• Check the specification.
• Check the program.
• Check the program.
• Check the parameter.
• Check the specifications.
• Check the program.
• Correct the normal line control axis.
• Delete the plane selection command (G17,
G18, G19) from the program for normal line
control.
• Check the specifications.
• Refer to "Mitsubishi CNC 700/70 Series
Programming Instruction Manual (Machining
Center Series)" for further details of usable G
commands.
• When the basic specification parameter
"#1229 set01/bit3" is ON, turn the parameter
OFF or specify the constant surface speed
control cancel (G97).
• Refer to "Mitsubishi CNC 700/70 Series
Programming Instruction Manual (Machining
Center Series)" for further details of usable G
commands.
• Refer to "Mitsubishi CNC 700/70 Series
Programming Instruction Manual (Machining
Center Series)" for further details of usable G
commands.