4 Process Data Mapping

The setting of the process data assignment is possible via the KEB-specific parameters
(fb10-fb19). After successful adjustment of the process data mapping the process data
can be processed by the G6 device.
After loading of the default values, a standard process data mapping is already set. The
number of each mapped parameters (fb14, fb19) has to be written once (default value
2) to activate the process data. Then the numbers are stored non-volatile.
In addition, the IO-link master must release the output process data via the master
command (value 0x98).
4.1 Output process data (manager => client)
Id-Text
Name
fb10
PD out index
Type
Array
Meaning
Number of subindices of this object
Data length
8 bit
Access
read
Coding
4
Standard value: 4
Note
-
Meaning
Default up to 4 parameter addresses to be used as process
data. Only parameters may be used that are allowed as process
data.
Data length
16 bit
Access
read / write
Coding
0000h...7FFFh
Standard value: 0000h
Note
-
Process Data Mapping
Parameter index
0x218A
Subindex 0
Subindex 1...4
31