KEB COMBIVERT G6 Programming Manual page 44

Table of Contents

Advertisement

General Control Card Parameters (Operator Functionality)
44
Id-Text
Name
os09
PU max invbusy retries
Meaning
Number of repetitions that are sent on the internal bus from the
power module to the controller if it rejects "inverter busy" error.
Type
Variable
Data length
8 bit
Access
read / write
Coding
0...255
Standard value: 200
Note
-
Id-Text
Name
os10
PU tout count
Meaning
Counts the timeouts on the internal bus between control and
power unit.
Type
Variable
Data length
16 bit
Access
read / write
Coding
0...65535
Standard value: 0
Note
-
Id-Text
Name
os12
operator command
Meaning
Default of instructions according to coding (see below)
Type
Variable
Data length
8 bit
Access
read / write
Coding
0: no
1: Load default values in all operator parameters
2: reinitialize PU-parameter image
Standard value: 0
Note
-
Parameter index
0x2089
Parameter index
0x208A
Parameter index
0x208C