KEB COMBIVERT G6 Programming Manual page 46

Table of Contents

Advertisement

General Control Card Parameters (Operator Functionality)
46
Id-Text
Name
os15
store mode
Meaning
The memory type of non-volatile parameters must be adjust-
ed with this parameter. The parameters will not be stored if
the value is "0", the device automatically changes to value "1"
after the next "power down". This value is the default value, the
non-volatile parameters are always stored. Value „2" deacti-
vates the storing, also over the next start of the module.
Type
Variable
Data length
8 bit
Access
read / write
Coding
0: off, curr. off / on at startup
1: on, always store
2: off, never store
Standard value: 1
Note
-
Id-Text
Name
os17
safety type
Meaning
Type of safety module
Type
Variable
Data length
16 bit
Access
read
Coding
0: no safety module available
1: Type 1 (STO)
Standard value: 0
Note
-
Id-Text
Name
os18
safety software date
Meaning
Displays the software date of the safety module.
Type
Variable
Data length
32 bit
Access
read
Coding
0.0000...9999, 1231:
The year is displayed before the comma, month and day are
after that. 2012,0813 means 13.08.2012. If no safety module is
installed, the value "0: no safety functionality" is displayed.
Standard value: 0
Parameter index
0x208F
Parameter index
0x2091
Parameter index
0x2092

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents