IO-Link Interface
Individual values are displayed as COMBIVIS parameters:
An addressing of the device is not necessary, because IO-Link connections are always
1:1 connections with the master. A master can have multiple output ports.
26
Id-Text
Name
fb03
Unit identification
Meaning
Unit identification number
Type
Variable
Data length
32 bit
Access
read
Coding
0...FFFFFFh
Standard value: 0
Note
Any combination of G6 power unit config ID and control card
config ID has its own deviceID (reference table)
Id-Text
Name
fb05
IO-Link baud rate
Meaning
Baud rate IO-Link bus
Type
Variable
Data length
8 bit
Access
read
Coding
1: 4.8 kBd (COM1)
2: 38.4 kBd (COM2)
3: 230.4 kBd (COM3)
Standard value: 2: 38.4 kBd
Note
Baud rate not changeable.
Parameter index
0x2183
Parameter index
0x2185