• Do not discharge batteries to a level below 14 V under load. Deep discharge below
14 V will deteriorate the battery performance.
• Never puncture the battery cells. Punctured cells may cause fire.
Operating temperatures
• Charge temperature 
Recommended: 10°C - 30°C (50°F - 86°F), Max.: 5°-40°C (41°F - 104°F)
• Discharge temperature: -10°C – 40°C (14 - 104°F)
• Storage temperature: 5°C – 25°C (41°F and 77°F)
Figure 2-22. Temperature depending LiPo battery capacity
Battery life
Batteries that lost 20% of their capacity (see section
must be removed from service and disposed of properly.
Disposal
For proper treatment, recovery and recycling, please take these products to designated
collection points, where they will be accepted on a free of charge basis. Alternatively,
send the battery for disposal back to Intel. Disposing of this product correctly will be
help to save valuable resources, and prevent any potential negative effects on human
health and the environment, which could otherwise arise from inappropriate waste
handling. For disposal please discharge the battery to 3V/Cell or below, then wrap the
battery in a bag for disposal.
Product warranty
Product warranty is limited to original defects in material and workmanship. Warranty
does not cover collateral damage. Due to the nature and use of this product there is no
term warranty. Misuse, abuse, incorrect charging, failure to comply with the above
warnings and guidelines, and other inappropriate use of this product are not covered
under warranty.
®
TM
Intel
Falcon
F8+
The capacity of LiPo batteries drops dramatically if the
temperature is below 5° C. Please keep the batteries
warm when flying in cold conditions, or even heat
them up before to approx. 30° C.