Installation Procedure; Installation Diagram Of Indoor And Outdoor Units - Toshiba RAS-13G2KCVP-T Service Manual

Table of Contents

Advertisement

10-1. Installation Diagram of Indoor and Outdoor Units

3
Batteries
2
Wireless remote control
Remark :
• Detail of accessory and installation parts can
see in the accessory sheet.
• Some pictures might be different from the
actual parts.
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (- ) positions.

10. INSTALLATION PROCEDURE

6
Flat head
4
Remote control holder
wood screw
Vinyl tape
Apply after carrying
out a drainage test.
Before installing the wireless remote controller
2 Wireless remote controller
Hook
1
Installation
plate
Bush body
Shield pipe
Saddle
Extension
drain hose
(Not available,
provided by installer)
- 59 -
FILE NO. SVM-15058
For the rear left and left piping
Wall
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose sloped
downward.
The auxiliary piping can be connected to
the left, rear right, right or bottom right.
Rear
right
Bottom
Rear
right
left
Bottom left
Insulate the refrigerant pipes separately
with insulation, not together.
6 mm thick heat resisting
polyethylene foam
3 Batteries
Left

Hide quick links: