10-1. Installation Diagram of Indoor and Outdoor Units
Flat head
wood screw
7
Battery
cover
#
"
Flat head
wood screw
Batteries
3
5
Filter
7
Flat head
wood screw
2
Wireless remote control
The provided Remote Controller is a wireless
type, which also can be used as a wire.
Please see "How to Connect The Remote
Controller for Wired Operation", in case of
wired control is required.
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (−) positions.

10. INSTALLATION PROCEDURE

Refrigerant piping
must be protected
from physical
damage.
Install a plastic
cover or equivalent.
Vinyl tape
Apply after carrying
out a drainage test.
4
Remote control holder
Before installing the wireless remote controller
2 Wireless remote controller
Hook
Installation
1
plate
Shield pipe
Saddle
Extension drain hose
(Not available, provided
by installer)
- 56 -
FILE NO. SVM-18033
For the rear left and left piping
Wall
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Left
Bottom
Rear
right
left
Bottom left
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose sloped
downward.
The f are connection should be installed
outdoors.
Insulate the refrigerant pipes separately
with insulation, not together.
6 mm thick heat resisting
polyethylene foam