Specifications Of Electrical Parts - Toshiba RAS-13G2KCVP-T Service Manual

Table of Contents

Advertisement

6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
Part s n ame
No.
1
Fan motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
Heat exchanger temp. sensor (TCJ-sensor)
4
5
Louver motor
6-2. Outdoor Unit
No.
1
Reactor
2
Outdoor fan motor
3
Suction temp. sensor (TS sensor)
4
Discharge temp. sensor (TD sensor)
5
Outside air temp. sensor (TO sensor)
6
Terminal block (5P)
7
Compressor
Coil for PMV
8
Parts name
(10,13k)
(18k)
Type
MF-340-30-3
( - )
(
)
-
(
)
-
MP24Z4N
Model name
CH-69-Z-T
L = 19mH, 10A
ICF-140-43-4R
DC140V, 43W
(Inverter attached)
10kΩ (25°C)
(Inverter attached)
62kΩ (20°C)
(Inverter attached)
10kΩ (25°C)
JXO-5B
20A, AC250V
DA108X1C-23FZ
3-phases 4-poles 750W
DA131S1B-31FZ
3-phases 4-poles 1100W
CAM-MD12TCTH-5
DC12V
- 19 -
FILE NO. SVM-15058
Specif icat io ns
DC250~370V, 30W
10k
at 25°C
10kΩ at 25°C
10kΩ at 25°C
Output (Rated) 1W, 16 poles, DC12V
Rating