Installation Procedure - Toshiba RAV-SM560KRT-E Installation Manual

Hide thumbs Also See for RAV-SM560KRT-E:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
2

INSTALLATION PROCEDURE

Installation Diagram of Indoor Unit
For rear left and side pipe exit
Insert the cushion between the
indoor unit and wall, and lift indoor
unit to make work easier.
Do not allow the drain hose to sag.
Cut the piping hole
sloped slightly
Make sure to run the drain hose
sloped downward.
Mounting the Installation Plate
For installation of the indoor unit,
use the paper template included.
When the installation plate is directly mounted on the wall
1. Securely fix the installation plate to the wall by screwing it through the upper and lower fixing holes.
2. To mount the installation plate on a concrete wall with anchor bolts, utilize the anchor bolt holes as illustrated in
the above figure.
3. Attach the installation plate horizontally to the wall.
When installing the installation plate with mounting screw, do not use the anchor bolt hole.
Otherwise the unit may fall down and result in personal injury and property damage.
Ø5mm hole
Clip anchor
(local parts)
Wall
Hook
Mounting screw
Ø4 x 25mm
Hook
1 Installation
plate
Pipe
insulation
Mounting screw
Hook
1 7 0
1 2 0
10 0m m
Hook
Pipe hole
Indoor unit
Thread
CAUTION
4
Insulate the refrigerant pipes
separately with insulation, not together.
Min. 6 mm thick heat resisting polyethylene foam
The auxiliary piping can be connected
the left, rear left, rear, right or bottom.
Right
Rear
Bottom
Rear left
55
18 0
80 10 0
0
10 0m m
Weight
Hook
Mounting screw
Pipe hole
Anchor bolt
Projection
15mm or less
Left
65
Installation
plate
Indoor unit

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rav-sm560at-eRav-sm800krt-eRav-sm800at-e

Table of Contents