7. Louver control

This function controls the air direction of the indoor unit.
1) Louver
• The position is automatically controlled according to the operation
position
mode (COOL/HEAT).
• The set louver position is stored in memory by the microcomputer,
and the louver returns to the stored position when the next operation
is performed. (Cooling/Heating memory position)
The angle of the louver is indicated as the louver closes fully is 0°.
1) Louver position in cooling operation
Manual and automatic operation
Initial setting is directs downward (13.4°)
Wide-angle
Left side lover setting is left facing (45.9°)
Right side lover setting is right facing (45.9°)
Wide front
Left side lover setting is front facing (0°)
Right side lover setting is front facing (0°)
Operation flow and applicable data, etc.
HI-POWER operation
Default setting is directs downward (26.1°)
Wide air direction
Wide position is directs downward (13.4°)
Right wide
Left side lover setting is front facing (0°)
Right side lover setting is right facing (45.9°)
Spot air direction
Spot position is directs downward (43.1°)
Sport right
Left side lover setting is right facing (45.9°)
Right side lover setting is right facing (45.9°)
- 34 -
FILE NO. SVM-15058
Description
Left wide
Left side lover setting is left facing (45.9°)
Right side lover setting is front facing (0°)
Spot left
Left side lover setting is left facing (45.9°)
Right side lover setting is left facing (45.9°)