11-9-3. Indoor Unit (Other Parts)
No.
Part name
1
Room temp. (TA) sensor
Heat exchanger (TC,TCJ)
sensor
2
Remote controller
3
Louver motor
MP24Z4N
4
Indoor fan motor
11-9-4. Outdoor Unit
No.
Part name
1
Compressor
Model : DA108X1C-23FZ (RAS-10, 13)
Model : DA131S1B-31FZ (RAS-18)
2
Outdoor fan motor
(Model : ICF-140-43-4R)
3
Pulse motor valve coil
Model : CAM-MD12TCTH-5
4
Outdoor temperature sensor (TO),
discharge temperature sensor (TD),
suction temperature sensor (TS).
Disconnect the connector and measure the resistance value with tester.
(Normal temp.)
Temperature
Sensor
TA, TC, TCJ (kΩ)
Refer to 11-5-1. (5).
Measure the resistance value of each winding coil by using the tester.
(Under normal temp. 25°C)
White
1
1
Yellow
2
2
Yellow
3
3
Yellow
4
4
Yellow
5
5
Refer to 11-5-1. (3) and (4).
Measure the resistance value of each winding by using the tester.
Red
White
Black
Measure the resistance value of winding by using the tester.
Red
White
Black
Measure the resistance value of winding by using the tester.
1
W
GR
COM
6
3
O
COM
Disconnect the connector, and measure resistance value with the tester.
(Normal temperature)
Sensor
TD (kΩ)
TO,TS (kΩ)
- 96 -
FILE NO. SVM-15058-1
Checking procedure
10°C
20°C
20.7
12.6
Position
1 to 2
1 to 3
1 to 4
1 to 5
Checking procedure
Position
DA108X1C-23FZ DA131S1B-31FZ
Red - White
White - Black
0.88 to 0.98Ω
Black- Red
Position
Red - White
White - Black
Black- Red
Model : CAM-MD12TCTH-5
Position
Red - White
White - Orange
Brown- Yellow
Y
R BL
2
5
4
Brown- Blue
Temperature
10°C 20°C 25°C 30°C 40°C 50°C
100
62
20.7 12.6 10.0
25°C
30°C
40°C
10.0
7.9
4.5
Resistance value
200 ± 14Ω
Resistance value
0.92 to 1.02Ω
Under 20°C
Resistance value
20 to 22Ω
20 to 22Ω
20 to 22Ω
Under 20°C
Resistance value
43 to 49Ω
43 to 49Ω
43 to 49Ω
43 to 49Ω
Under 20°C
50
41
27
18
7.9
4.5