10-5-2. Power Supply and Connecting Cable Connection
Connecting CABLE
Stripping length of the connecting cable
Earth line
50 mm
10 mm
3
10 mm
45 mm
1. The power supply must be same as the rated of air conditioner.
2. Prepare the power source for exclusive use with air conditioner.
3. Circuit breaker must be used for the power supply line of this air conditioner.
4. Be sure to comply power supply and connecting cable for size and wiring method.
5. Every wire must be connected fi rmly.
6. Perform wiring works so as to allow a general wiring capacity.
7. Wrong wiring connection may cause some electrical part burn out.
8. Incorrect or incomplete wiring is carried out, it will cause an ignition or smoke.
9. This product can be connected to main power supply.
Connection to fixed wiring : A switch which disconnects all poles and has a contact separation at least 3mm must be
incorporated in the fixed wiring.
Power Supply Input at Outdoor Unit Terminal Block (Optional)
Indoor Unit
Connecting cable connect to
terminal block (1, 2, 3, ˙)
Connecting cable
Terminal block
30
CAUTION
- 72 -
FILE NO. SVM-15058
Outdoor Unit
Connecting cable
Power cord
1 2 3
40
30
Earth line
Connecting cable
L N
40
Earth line
Power cord

Hide quick links: