Item
Operation flow and applicable data, etc.
9..Temporary
Pressing [RESET] button starts the temporary operation
operation
of [AUTO] operation. When keeping [RESET] button
pressed for 10 seconds or more, the temporary [COOL]
operation is performed.
Filter lamp ON
NO
Did you press [RESET] button
for 3 seconds or more?
YES
Did you press [RESET] button
for 10 seconds or more?
YES
Did you press [RESET] button
for 20 seconds or more?
YES
Quiet Setting
10. Plasma
This function generates nagative ion while cleaning the air in the room.
ionizer
If plasma ionizer purifier-ON signal is received while the air conditioner stops, the plasma ionizer
purifier
purifier starts operation, and if it is received while the air conditioner operates, the air conditioner
control
and the plasma ionizer purifier start operation.
Present status
Stop
Plasma ionizer purifier only
Air conditioner
Joint use of AC and plasma ionizer purifier
Plasma ionizer purifier operation
AC + Plasma ionizer purifie operation
Sending plasma ionizer-ON
1
Air conditioner stops
Operation lamp ON
* 1
Memory position of
louver/COOL
* 2
Fan ON
Plasma ionizer purifier ON
Plasma ionizer purifier operation
YES
Press RESET button.
NO
Temporary [AUTO] operation
NO
Switch to [AUTO RESTART] Control
NO
Temporary [COOL] Operation
Operation button
PURE button
Plasma ionizer purifier
Stop (All)
AC + Plasma ionizer purifier
AC + Plasma ionizer purifier
AC operation
Louver*1
Cooling position
AUTO, L, L+, M, M+, H
Follows to AC operation
2
1 , 2
Air conditioner operates
Start of plasma ionizer purifier-ON
Air conditioner + Plasma
ionizer purifier operate
1 When pressing [RESET] button, the
2 When keeping [RESET] button
3 When keeping [RESET] button
pressed for 10 seconds or more, "Pi"
sound is heard and the temporary
[COOL] operation starts.
4 To stop the temporary operation, press
* When the previous operation was the
operation of air conditioner + plasma
ionizer purifier, an operation of air
Air conditioner
conditioner + plasma ionizer purifier starts
AC operation*
by pushing AC button on the remote
controller.
(Operation of air conditioner + plasma
All stop
ionizer purifier is stored in memory.)
All stop
*1 Swing is available
Fan speed *2
*2 Fan speed is Fan Auto mode varies in
Follows to AC operation
Sending plasma ionizer purifier-OFF
3
Plasma ionizer purifier
operates
Operation lamp OFF
Fan stop
Plasma ionizer purifier-OFF
Louver close
All stop
- 38 -
FILE NO. SVM-15058
Description
temporary [AUTO] operation starts.
pressed for 3 seconds or more, Pi, Pi, Pi
sound is heard and [AUTO RESTART]
control is changed.
the button again.
order, (M + 1) → (L) → (L–) → (SL).
, 4
3
Air conditioner +
Plasma ionizer purifier
operate
Filter-OFF
Air conditioner operates
4

Hide quick links: