8. ECO
When pressing [ECO] button on the remote controller, a
operation
Economic operation is performed.
<Cooling operation>
This function operates the air conditioner with the difference
between the set and the room temperature as shown in the
following figure.
°C
6.5
6.0
5.5
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
TSC
-0.5
-1.0
-2.0
1H
Operation flow and applicable data, etc.
2H
3H
4H
* 12 (DRY max - COOL min) /6 x 5 + COOL min
* 11 (DRY max - COOL min) /6 x 4 + COOL min
* 10 (DRY max - COOL min) /6 x 3 + COOL min
* 9 (DRY max - COOL min) /6 x 2 + COOL min
* 8 (DRY max - COOL min) /6 x 1 + COOL min
Hz
10G2KCVP-T 13G2KCVP-T 18G2KCVP-T
Cool min
10
DRY max
30
Zone Frequency
FAN
Dry Max
12
11
*12
10
*11
*10
9
*9
8
7
*8
6
5
4
3
2
Min
1
Hz
OFF
Time
9
9
30
30
- 37 -
FILE NO. SVM-15058
Description
<Cooling operation>
1) The control target temperature
increase 0.5ºC per hour up to 2ºC
starting from the set temperature
when ECONO has been received.
2) The indoor fan speed is depend
on presetting and can change
every speed after setting ECO
operation.
3) The compressor speed is
controlled as shown in the left
figure.