10-1. Installation Diagram of Indoor and Outdoor Units
Batteries
3
6
Flat head
wood screw
Remote control holder
2
Wireless remote control
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (-) positions.

10. INSTALLATION PROCEDURE

Refrigerant piping
must be protected
from physical
damage.
Install a plastic
cover or equivalent.
Vinyl tape
Apply after carrying
out a drainage test.
4
Before installing the wireless remote controller
2 Wireless remote controller
Hook
1
Installation
plate
Shield pipe
Saddle
Extension drain hose
(Not available,
provided by installer)
- 49 -
FILE NO. SVM-19002
For the rear left, bottom left and left piping
Wall
Cut out a piece of SPACER from indoor
unit packaging box, roll it and insert
between the indoor unit and wall to tilt
the indoor unit for better operation.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Bottom
Rear
right
left
Bottom left
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose sloped
downward.
Insulate the refrigerant pipes separately
with insulation, not together.
8 mm thick heat resisting
polyethylene foam
3 Batteries
Left