No.
Part name
Plasma-ion
7
charger, High
volt generator
Work procedure
1) Follow to the procedure in the item
2) Remove 5 screws and remove the ion-
charger assembly from the frame.
3) Remove the Plasma-ion charger from the High
volt generator assembly.
4) Remove cover of HV generator by unlock
4 claws.
5) Remove the board of HV generetor.
<Points to note during re-installation>
- Lay the wires straight, such that they pass
through the earth wire in a U-shape.
- Lay the wires such that the high voltage power
supply line passes in a U-shape.
5
- 104 -
FILE NO. SVM-15058-1
Remarks
5 Screws
Plasma-ion
U-shape groove
HV power supply
U-shape groove for
high- voltage power
supply's lead
4 Claws
Ground lead