No.
Part name
Fan motor
9
Work procedure
1) Follow the procedure
2) Remove 3 fixing screws, then remove
Cover motor assembly.
3) Loosen the set screws of the transverse
fan from the vent.
4) Remove 2 screws from the Motor-
band (right)
5) Pull the motor band(right) and the Fan-
Motor outward.
<Point to note during re-installation>
For the position of the fan motor, please install
such that the fan motor connector matches
the position and enters the space of the ribs
of the motor band(right).
-
and
6
8
1
- 106 -
FILE NO. SVM-15058-1
Remarks
Fixing screw
Set screw
Screws
Motor band(right)
Motor connector