Specifications Of Electrical Parts - Toshiba RAS-25S4KVPG-ND Service Manual

Hide thumbs Also See for RAS-25S4KVPG-ND:
Table of Contents

Advertisement

6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
Parts name
No.
1
Fan motor (For indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
Heat exchanger temp. sensor ( TCJ-sensor )
4
5
Louver motor (Horizontal) 2 pcs.
6
Louver motor (Vertical) 2 pcs.
7
Louver motor (Thermal sensor)
6-2. Outdoor Unit
Parts name
No.
1
Reactor
2
Outdoor fan motor
3
Suction temp. sensor (TS sensor)
4
Discharge temp. sensor (TD sensor)
5
Outside air temp. sensor (TO sensor)
6
Heat exchanger temp. sensor (TE sensor)
7
Terminal block (6P)
8
Compressor
RAS-25S4AVPG-ND
RAS-35S4AVPG-ND
9
Coil for PMV
10
Coil for 4-way valve
11
Heater cord
Type name
ICF-340-30-7B
(-)
(-)
(-)
MSBPC20F04
24BYJ48-ST
MSBPC20F04
Type name
CH-102
ICF-340-A70-1
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
JX0-6B
N-RT13ND1B
N-RT15ND1B
PQ-M10012-000313
STF-H01AJ1872A1
CSC-2 100W
- 19 -
Specifications
DC280~340V, 42W
10kΩ at 25°C
10kΩ at 25°C
10kΩ at 25°C
Output (Rated) 4 phase, DC12V
Output (Rated) 4 phase, DC12V
Output (Rated) 4 phase, DC12V
Specifications
L = 16.9 ~ 19.1mH, 16A
DC140-340V, 70W
10kΩ (25°C)
62kΩ (20°C)
10kΩ (25°C)
10kΩ (25°C)
30A, AC600V
3-Phases (6-Poles) ; 1385W
3-Phases (6-Poles) ; 1585W
DC12V
AC220-240V
100W

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-25s4avpg-ndRas-35s4kvpg-ndRas-35s4avpg-nd

Table of Contents