Specifications Of Electrical Parts - Toshiba RAS-B07G3KVSG-E Service Manual

Indoor/outdoor unit, r32 or r410a inverter
Hide thumbs Also See for RAS-B07G3KVSG-E:
Table of Contents

Advertisement

6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
No.
1
Fan Motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Heat exchanger temp. sensor (TCJ-sensor)
5
Louver motor
6-2. Outdoor Unit
No.
1
Compressor
2
Fan Motor
3
Pulse Modulating Valve (PMV) coil
4
4-Way valve coil
5
Reactor
6
Suction temp. sensor
7
Discharge temp. sensor
8
Outside air temp. sensor
9
Heat Exchanger temp. sensor
10
Terminal block
Parts name
Parts name
RAS-07, 10
RAS-13
RAS-16
RAS-07,10, 16
RAS-13
RAS-16
(TS sensor)
(TD sensor)
(TO sensor)
(TE sensor)
(5 poles)
Type name
ICF-340-30-6
(-)
(-)
(-)
24BYJ48-ST, MSBPC20F04
Type name
KSK75D43UEZA
KSK89D53UFZ
KSN108D22UFZ
WDF-340-A43-1
PQ-M10012-000313
SQ-A2522G-000352
DXQ-939
CH-69-Z-T
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
JXO-5B
- 22 -
Specifications
DC340V, 42W
10kΩ at 25°C
10kΩ at 25°C
10kΩ at 25°C
Output (Rated) 4 phase, DC12V
Specifications
3-Phases (6-Poles) ; 550W
3-Phases (6-Poles) ; 620W
3-Phases (6-Poles) ; 890W
DC 140-340V ; 43W
DC 12V
AC 220-240V
AC 220-240V
L = 19mH, 10A
10kΩ at 25°C
62kΩ at 20°C
10kΩ at 25°C
10kΩ at 25°C
AC 250V, 20A