6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Outdoor Unit
No. Parts name
1
Compressor
2
Outdoor fan motor
3
Reactor
4
Reactor
5
4-way valve coil
6
PMV coil
7
P.C. board (Main PCB)
8
P.C. board (Control PCB)
9
P.C. board(Display PCB)
10
Fuse (Mounted on P.C. board WP-044)
11
Fuse
12
Fuse (Mounted on P.C. board WP-044,
WP-514)
13
Outdoor temp. sensor (TO sensor)
14
Evaporator temp. sensor (Te sensor)
15
Discharge temp. sensor (Td sensor)
16
Suction temp. sensor (Ts sensor)
17
Temp. sensor at A room gas side
(TGA-sensor)
18
Temp. sensor at B room gas side
(TGB-sensor)
19
Terminal block (6P)
20
Terminal block (3P)
21
High-pressure SW
Model name
2M10
KSK89D53UFZ
2M14
KTN130D30UFZ
WDF-340-A43-1
CH-69-Z-T
CH-76
SQ-A2522G-000352
PQ-M10012-001382
WP-044
WP-514
MCC-1646
ACB-1UB177W
- 25 -
Rating
3-Phases(6-Poles);715W
3-Phases (6-Poles);1075W
Output 43W
L=19mH、10A
9.9mH、1A
AC220-240V
DC12V
AC220-240V
AC220-240V
DC5V
AC250V、25A
AC250V、3.15A、6.3A
AC250V、3.15A
10kΩ (25℃)
10kΩ (25℃)
50kΩ (25℃)
10kΩ (25℃)
10kΩ (25℃)
10kΩ (25℃)
AC600V、30A
AC250V、20A
OFF:4.50MPa