6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
No.
1
Fan Motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Heat exchanger temp. sensor (TCJ-sensor)
Louver motor (Horizontal) x 1 pcs.
5
Louver motor (Vertical) x 2 pcs.
6-2. Outdoor Unit
No.
1
Compressor
2
Fan Motor
3
Pulse Modulating Valve (PMV) coil
4
4-Way valve coil
5
Reactor
6
Suction temp. sensor
7
Discharge temp. sensor
8
Outside air temp. sensor
9
Heat Exchanger temp. sensor
10
Terminal block
Parts name
Parts name
RAS-22
RAS-24
RAS-22
RAS-24
RAS-22
RAS-24
RAS-22
RAS-24
(TS sensor)
(TD sensor)
(TO sensor)
(TE sensor)
RAS-22(5 poles)
RAS-24(6 poles)
Type
ype
ICF-340-30-6
(-)
(-)
(-)
24BYJ48-ST
MSBPC20F04
Type name
KTN130D30UFZ
DX151A1T-30N
WDF-340-A43-1
ICF-340-A70-1
PQ-M10012-000313
SQ-A2522G-000352
SQ-D27012-000752
CH-69-Z-T
CH-47-Z-T
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
JX0-5B
JX0-6B
- 22 -
FILE NO. SVM-18033
Specificat
DC-340V, 42W
10kΩ at 25°C
10kΩ at 25°C
10kΩ at 25°C
Output (Rated) 4 phase, DC12V
Output (Rated) 4 phase, DC12V
Specifications
3-Phases (6-Poles) ; 1075W
3-Phases (4-Poles) ;
1170W
DC 140-340V ; 43W
DC 140-340V ; 70W
DC 12V
AC 220-240V
DC 12V
L = 19mH, 10A
L = 7.6~8.4mH, 16A
10kΩ at 25°C
62kΩ at 20°C
10kΩ at 25°C
10kΩ at 25°C
AC 250V, 20A
AC 600V, 30A