UL Installation Requirements

The following requirements apply to both UL Residential and UL Commercial Burglary installations:
All partitions must be owned and managed by the same person(s).
All partitions must be part of one building at one street address.
The audible alarm device(s) must be placed where it/they can be heard by all partitions.
The control cabinet must be protected from unauthorized access. This can be done by installing a tamper switch on the
cabinet door (not supplied with VISTA-128BPT/VISTA-250BPT) or by installing a UL Listed passive infrared detector
positioned to detect cabinet access. Wire the selected device to any EOLR-supervised zone (Zone 1-8). Program this zone
for day trouble/night alarm (type 05) or 24-hour audible alarm (type 07) response. The 24-hour alarm response must be
used for multiple-partitioned systems.
Remote downloading and auto-disarming are not UL Listed features.
NOTE: UL Commercial Burglary installations require the attack resistant cabinet. The cabinet is included in the VISTA-
ULKT kit.
UL609 Local Mercantile Premises/Local Mercantile Safe & Vault
Use the following guidelines for a Local Mercantile Premises/Local Mercantile Safe & Vault installation:
All zones must be configured for EOLR supervision (∗41=0). Wireless sensors may not be used. If 4190WH V-Plexs are
used set field ∗24 to "0" to enable tamper detection.
Attach a door tamper switch (supplied) to the VISTA-128BPT/VISTA-250BPT cabinet backbox. For safe and vault
installations, a shock sensor (not supplied) must also be attached to the backbox. (Also see SECTION 3: Installing the
Control)
Wire an ADEMCO AB12M Bell/Box to the bell output. Bell wires must be run in conduit. Program the bell output for a
timeout of 16 minutes or longer timeout and for confirmation of arming ding. (Also see SECTION 3: Installing the Control.)
Wire the VISTA-128BPT/VISTA-250BPT tamper switch and AB12M Bell/Box tamper switches to any EOLR-supervised
zone (zones 1-8). Program this zone for day trouble/night alarm (type 05) or 24-hour audible alarm (type 07) response. The
24-hour alarm response must be used for multiple-partitioned systems.
Entry delays must not exceed 45 seconds, and exit delays must not exceed 60 seconds.

UL365/UL609 Bank Safe and Vault Alarm System

Follow the instructions for UL609 local installations above and Bank/Mercantile Safe and Vault (page 3-2) sections of this
manual.
Bell 1 Confirmation of Arming Ding (∗16) must be set to 1 to on (enabled) (will automatically test bell).
Entry delays or any other delays to report alarms may not exceed 45 seconds.
Models 7847i, 7847i-E, IGSMV, and IGSMHS
Bell Timeout must be programmed for 16 minutes min. (See Section 5, page 5-2)
Two 17.2AH Batteries must be used for this application.
The main protective circuits, linings and attachments on the safe and vault, control units and alarm housing must be of the
normally closed circuit, fully supervised type.
To be installed inside the safe or vault.

UL365 Police Station Connected Burglar Alarm

Follow the instructions for UL609 local installations given above.
For Systems without Line Security:
You may use the VISTA-128BPT/VISTA-250BPT dialer alone, or the 7847i Communicator alone.
When using the dialer, program it to send Burglary Alarm, Low Battery, and Communicator Test reports. Field ∗27 must
be set to "0024" (or less).
If you are using the 7847i Communicator, connect it to the VISTA-128BPT/VISTA-250BPT burglary/audible panic alarm
trigger.