Keypad
&
Display Description
Operator's Manual
about two seconds, until you hear a key click,
then the memory will be reset.
@
MAN OVER BOARD (MOB)
Version 7.5
This dedicated function key is located at the bottom right hand corner
of the front panel. When depressed for a few seconds, it activates a
number of automatic functions:
~
Most obviously; it brings up an MOBt (Plot) screen. This is an
automatic scaling screen which selects the best zoom level to
display your present position and the MOB position. In addition,
the MOB position is displayed in the upper left corner, so that you
can quickly read the coordinates to others who may be available
to render assistance. This plot screen also provides the vital bear-
ing and distance back to the MOB position, as well as your present
course over ground.
~
The MOB position, date and time are stored in the Waypoint Bank
for future reference (e.g. log book entries).
~
Navigation data output on the NMEA ports (i.e. BWe and BWR),
are changed to reflect the current crisis situation. This way, other
interfaced equipment can also help guide you back to the MOB
position. When the MOB condition is canceled via a MOB screen
softkey, the NMEA sentences will automatically revert to the ac-
tive route information. Don't forget to cancel the MOB so your
interfaced equipment will read the correct data!
~
The MOB function key and remote MOB input are disabled from
subsequent activation, until theMOB Cancel softkey is selected.
~
Other functions such as Position and Navigate can still be ac-
cessed; however, the screen will revert to the MOB Plot screen
after 30 seconds. Bearing and distance information in these other
screens relate to the MOB position, not the next waypoint in the
active route, until MOB is canceled.
To cancel a MOB condition, make sure you are in the MOB Plot screen.
Press the Efunction key, then select the Cancel MOB softkey.
This MX420 receiver is also capable ofperforming the MOB function
from a remote contact closure. If the contact closure is made for less
than 2 seconds, the input is registered as a Mark Position. If the con-
tact closure is made for more than 2 seconds, the input is registered as
73