Displaying Alarms Present On Your Switch - HP FlexFabric 12500E Installation Manual

Routing switch
Table of Contents

Advertisement

Temperature: 28 ℃
High temperature alarm threshold: 60 ℃
Low speed alarm threshold: 30 %
Fan
Status
---
----------
1
normal
2
normal
3
normal
4
normal
5
normal
6
normal
7
normal
Table 16 Command output
Field
Fan-tray 1:
Speed(rpm)
Fan-tray verbose state on chassis 1:

Displaying alarms present on your switch

Use the display alarm command to display the alarming information about your switch.
In standalone mode:
<Sysname> display alarm
Slot
6
6
6
3
Table 17 Command output
Field
Slot
Level
Info
faulty
In IRF mode:
<Sysname> display alarm
Chassis
1
Speed(%)
----------
30 %
30 %
65 %
65 %
40 %
40 %
40 %
Level
Info
ERROR
Fan 2 is absent.
ERROR
Power 2 is absent.
ERROR
The board in slot 10 is faulty.
WARNING
The temperature of sensor 3 exceeds the lower limit.
Slot
Level
Info
6
ERROR
Fan 2 is absent.
Description
Indicates that the following information is for the fan in
tray number 1.
Rotate speed of the fan
Indicates that the following information is for the fan on
member switch 1
Description
Slot number of the alarmed card.
If the value is a hyphen (-), the alarm is generated by the chassis.
Alarm severity. Possible values include ERROR, WARNING,
NOTICE, and INFO, In the descending order.
Detailed alarm information.
The card is starting up or faulty.
64

Advertisement

Table of Contents
loading

Table of Contents