6.1 Single I/O Module - Siemens SINUMERIK 810D Configuration Manual

Hide thumbs Also See for SINUMERIK 810D:
Table of Contents

Advertisement

6 I/O modules

6.1 Single I/O module

SHIELD
M24Lo.
P24Logic
SHIELD
M24Po
P24Power
25
25
Fig. 6-2
Dimension drawing single I/O module
EMC measures
The single I/O module has an equipotential bonding connection at the front. A
low--resistance finely stranded connection cable to the grounding bar (see
Subsection 2.1.4) with a cross--section of at least 10 mm
interference currents. The connection must be as short as possible. In the case
of common protection and interference voltage, the protective conductor
regulations according to VDE 0100 and VDE 0160 must always be complied
with.
6-90
Ventilation gap 50mm
Ventilation gap 50mm
135
SINUMERIK 810D Manual Hardware Configuration (PHC) - - 11.02 Edition
70
Space for
front
connector
2
is required to divert
E Siemens AG, 2002. All rights reserved
05.98
12.95

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 810deSinumerik 810d powerlineSinumerik 810de powerline

Table of Contents