Table 4-8
The signals with a gray background are not assigned when a direct measuring system is
connected.
Signal names
<Signalname>i means signal of measuring system i where i = 1, ..., 6
PENC1/2
APi
ANi
ENCCLK
XENCCLK
THMOTi
ENCDATi
XENCDATi
DPi
DNi
XBMIDAT
THMOTCOM
Note
The encoder power supply is not automatically controlled; this means: no
Remote/Sense mode. As a result, the length of the encoder cable is limited.
S
S
S
E Siemens AG, 2002. All rights reserved
SINUMERIK 810D Manual Hardware Configuration (PHC) - - 11.02 Edition
Assignment of measuring system connection X411- -X416
Pin
Name
1
PENC1/2
2
M
3
APi
4
ANi
5
M
6
BPi
7
BNi
8
M
9
Unassigned
10
ENCCLK
11
Unassigned
12
XENCCLK
13
THMOTi
Encoder power supply (PENC1:
X411--X413, PENC2: X414--X416)
Incremental signal A
Incremental signal A
BMI clock signal
BMI clock signal
Motor temperature
BMI data signal
BMI data signal
Incremental signal D
Incremental signal D (not for direct measuring system)
BMI data signal
Motor temperature
EQN 1325:
ERN 1387:
External encoder with power consumption ± 300mA:
4 Description of the SINUMERIK 810D
4.2 Interfaces of the SINUMERIK 810D
X411- - X416
Type
Pin
Name
VO
14
PENC1/2
V
15
ENCDATi
I
16
M
I
17
RPi
V
18
RNi
I
19
CPi
I
20
CNi
V
21
DPi
- -
22
DNi
O
23
XENCDATi
- -
24
M
O
25
THMOTCOM
I
BPi
Incremental signal B
BNi
Incremental signal B
RPi
Incremental signal R
RNi
Incremental signal R
CPi
Incremental signal C
CNi
Incremental signal C
± 18m
± 25m
± 18m
Type
VO
B
V
I
I
I
I
I
I
B
V
I
4-61