The interfaces, operating and display elements of the CCU3 are the same as on
the CCU1/2 (see Subsection 4.2.3 with the following differences:
X307
Additional pulse interface (axis 3)
Connector designation:
Connector type:
X113. X114, X131
--
Operating and
The operating and display elements on the front panel of the CCU3 correspond
display elements
to Table 4-10, with the exception of the two bottom LEDs (see Fig. 4-3)
Table 4-11
LEDs
(left row)
LEDs
(right
row)
E Siemens AG, 2002. All rights reserved
SINUMERIK 810D Manual Hardware Configuration (PHC) - - 11.02 Edition
X307
20-pin ribbon cable, plug connector
are omitted
Meaning of the control LEDs on the CCU3 module
Desi-
Color
gnation
Green
+5V:
Red
NF:
Red
SF:
Yellow
CB:
Yellow
P24:
Green
PR:
Red
PS:
Red
PF:
Yellow
PFO: PLC FORCE status
Yellow
RST:
4 Description of the SINUMERIK 810D
4.2 Interfaces of the SINUMERIK 810D
Meaning
Lights up when supply voltages P5, P3V3,
Pcore and N5 are within the tolerance range.
Lights up when the NCK or the PLC watchdog
has responded.
Lights up if there are drive errors. Goes out after
the system is booted in error- -free condition.
Lights up when data transfer
takes place over the MPI interface.
Lights up if the 24 V power supply fails
PLC RUN status
PLC STOP status
Lights up if a PLC error occurs
Lights up briefly on reset
4-65