12.95
The DIP FIX switches inside the cable distributors 6FX 2006-1BA01 must be set
as follows:
Table 4-12
Switch
Open
Closed
Position of the
interfaces
Fig. 4-5
Connector X1- -X10
Table 4-13
E Siemens AG, 2002. All rights reserved
SINUMERIK 810D Manual Hardware Configuration (PHC) - - 11.02 Edition
Setting the DIP- -FIX switches (S1- -S6) in the cable distributor
S1
S2
x
1
2
3
4
X1
X2
X3
X4
X5 X6
S2
S5
S4
S6
X11
Position of the interfaces of the cable distributor
Connector assignments
Connector No.
Cable inlet
X1
1
1
(top)
X2
X3
2
2
X4
X5
3
X6
4
4
X7
X8
5
X9
6
7
X10
(bottom)
4 Description of the SINUMERIK 810D
4.2 Interfaces of the SINUMERIK 810D
S3
S4
x
x
x
5
6
7
Cable inlets
Terminal caps
Contact surfaces
Plug-in connectors X1...X10
X7
X8 X9
X10
Sub D socket connector
S1
S3
I/Os
1st handwheel
1st handwheel
2nd handwheel
2nd handwheel
2nd probe
Reserved
Reserved
Reserved
Reserved
1st probe
S5
S6
x
x
4-67

Hide quick links: