Ccu1: 6Th Axis (Sw 3.2 And Higher) - Siemens SINUMERIK 810D Configuration Manual

Hide thumbs Also See for SINUMERIK 810D:
Table of Contents

Advertisement

08.99
12.95
CCU1/2
S
S
CCU3
The PC card is only used for software upgrades or for standard software.
Caution
!
Removing or inserting the PCMCIA card when the system is energized results
in destruction of the PCMCIA card!
4.8

CCU1: 6th axis (SW 3.2 and higher)

Required
S
components
S
S
S
S
Design
Design:
Infeed module
-
1 3
axis CCU box with CCU1
1 power section with axis expansion plug- -in unit (single- -axis module )
1 power section with 611D closed- -loop control module (double- -axis module)
Fig. 4-19
Typical configuration
E Siemens AG, 2002. All rights reserved
SINUMERIK 810D Manual Hardware Configuration (PHC) - - 11.02 Edition
SW 2.x and lower:
The PC card is only used for software upgrades.
SW 3 and higher:
The PCMCIA card with the system software must remain inserted during
operation.
In addition to software upgrades, the PC card can be used as a memory for
series machine start-up; see
References: /IAC/ Installation Guide 810D.
611 digital closed-loop control
611D power section
Drive bus cable
Terminator for the drive bus
Device bus cable
4 Description of the SINUMERIK 810D
4.8 CCU1: 6th axis (SW 3.2 and higher)
6SN1118-0Djj1-0AAj
6SN112j-1AA0j-0jA1
6SN1161-1CA00-0jA0
6FX2003-0DA00
6FC5247-0AA28-0AA0
GWE: 462008006403
4-81