5.1 Single I/O Module; Terminal Block - Siemens SINUMERIK 840DE User Manual

Configuring the ncu sinumerik 840d series
Hide thumbs Also See for SINUMERIK 840DE:
Table of Contents

Advertisement

03.06
Technical data
Table 5-1
Power supply
for LOGIC (X1) and POWER (X5)
Current consumption
Power loss
Inputs
Outputs
Overtemperature protection
Coincidence factor
Total of all nominal currents within each
group of 0.5 A
Degree of protection
Weight
© Siemens AG, 2006. All rights reserved
SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition
Technical data of the single I/O module
– Nominal value
– Perm. range
– Ripple
– Polarity reversal protection
– Fuse-protection
– LOGIC
– POWER
– LOGIC
– POWER
Number of inputs
Signal level for signal "0"
Signal level for signal "1"
Isolation
Input current 1-signal
Input current 1-signal
Input current 0-signal
Delay time T
PHL
Delay time T
PLH
Noise immunity (DIN 57847)
Cable length terminal block
Number of outputs
Signal level for signal "0"
Signal level for signal "1"
Isolation
Short-circuit-proof
Max. output current
Switching frequency
Noise immunity (DIN 57847)
Cable length terminal block
5 I/O Modules

5.1 Single I/O module

DC 24 V
18.5 ... 30.2 V
3.6 V ss
yes
LOGIC: 1 A/250 V
POWER: no
type: 0.3 A , max. 1 A
max. 12 A
type: 7.2 W, max. 30.2 W
max: 362 W
64 digital inputs
–3 V to + 5 V
+ 15 V to +30 V
yes (optocoupler)
2–15 mA type: 6 mA
2–15 mA, type: 6 mA
–9 mA to 1 mA
0.5 to 3 ms
0.5 to 3 ms
2 kV
max. 3 m
32 digital outputs
open
U
– 0.5 V
Power
yes (optocoupler)
yes
resistive: 0.6 A
inductive: 0.6 A
lamp: 6 W
ohmic load: 100 Hz
inductive load: 2 Hz
lamp load: 11 Hz
2 kV
max. 3 m
block-specific shutdown
75%
IP20 or IPXXB
1.7 kg
5-65

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840dSinumerik 840d powerlineSimodrive 611 digital