CHAPTER 2. MMC Programming
[806] CARD PRE-INSTALL
Allows the pre-programming of a card slot for a specific card type. A card inserted into a
system will not be recognized by the system until it is enabled using this MMC. Cards in-
stalled using this MMC will not be assigned in the system numbering plan—you should
use MMC 724 to assign the desired directory numbers to extensions, trunks, ports or mis-
cellaneous functions.
DEFAULT DATA
NONE
ACTION
1. Press Transfer button and enter 806.
Display shows:
2. Enter cabinet number via dial keypad (e.g., 1)
OR
Press Volume button to make selection and
press Right Soft button.
3. Enter slot number via dial keypad (e.g., 6)
OR
Press Volume button to make selection and
press Right Soft button.
4. Dial 1 for YES to reset card or dial 0 for NO.
OR
Press Volume button to make selection and
press Right Soft button.
5. Dial 1 for YES to reset card or dial 0 for NO.
OR
Press Volume button to make selection and
press Right Soft button.
Samsung Business Communications
If a card is removed and a different card is inserted, and this MMC is performed,
the memory associated with the previous card (e.g., key programming) will be
erased.
OfficServ 7200 Programming Guide
DISPLAY
C:1–S:1
8 DLI 8 DLI
C:1–S:1
8 DLI 8 DLI
C:1–S:6
16 DLI 16 DLI
C:1–S:6
RESET CARD ? NO
C:1–S:6
ARE YOU SURE?NO