CHAPTER 2. MMC Programming
[423] S/T MODE
Allows the technician to select whether a BRI circuit is a station port or a trunk port.
No
Type
0
TRUNK
1
STATION
CONDITIONS
The BRI card must be installed in the system, otherwise the message 'NO BRI CARD' is
displayed.
DEFAULT DATA
NONE
ACTION
1. Press Transfer button and enter 423.
Display shows first BRI:
2. Dial trunk number (e.g., 727)
OR
Use Volume button to scroll through BRI numbers
and press Right Soft button to move cursor.
OR
Select all.
3. Enter circuit type (e.g. station).
OR
Press Volume button to select option and
press Right Soft button to return to step 2.
4. Press Transfer button to save and exit.
OR
Press Speaker button to advance to next MMC.
RELATED ITEMS
MMC 424
MMC 418
MMC 419
MMC 421
Samsung Business Communications
Description
The BRI trunk port used for ISDN trunk.
The BRI trunk port used for ISDN phone.
BRI S0 MAPPING
BRI AND PRI CARD RESTART
BRI OPTIONS
MSN DIGIT
OfficServ 7200 Programming Guide
DISPLAY
[725] S/T MODE
TRUNK
[727] S/T MODE
TRUNK
[ALL] S/T MODE
TRUNK
[727] S/T MODE
STATION
2-129