CHAPTER 2. MMC Programming
[500] SYSTEM-WIDE COUNTERS
Used to set the values of the system counters. The counters are listed below with a brief de-
scription of each.
No
Counter
0
ALARM REM.
CNTER
1
AUTO RDL
COUNTER
2
DISA CALL CNTER
3
DISA LOCK CNTER
4
NEW CALL
COUNTER
5
UCDS VISUAL
ALARM
6
UCDS AUDIO ALARM
7
UCD CS LEVEL 1
8
UCD CS LEVEL 2
DEFAULT DATA
SEE DESCRIPTION
Samsung Business Communications
Default
5
The number of times that an alarm reminder will
ring a station before cancelling. RANGE = 1-99.
5
The number of times the system will redial an out-
side number after the auto redial feature has been
activated. RANGE = 1-99.
99
Sets the maximum number of intercom calls that
can be made after accessing a DISA line.
RANGE = 1-99.
3
Number of attempts the system will allow to incor-
rectly access a DISA line before locking out the
DISA line. RANGE = -99
99
Number of times the system will allow a user to
signal New Call on a Trunk line during one call.
RANGE = 1-99.
0
Used to set the Visual alarm threshold. It is trig-
gered when the number of calls waiting to be an-
swered in the UCD group reaches this value.
RANGE = 0-25.
0
Used to set the Audio alarm threshold. It is trig-
gered when the number of calls waiting to be an-
swered in the UCD group reaches this value.
RANGE = 0-25.
0
Provides call wait indication level 1 if number of
calls waiting to be answered in UCD group reaches
this value. RANGE = 0-25.
0
Provides call wait indication level 2 if number of
calls waiting to be answered in UCD group reaches
this value. RANGE = 0-25.