Chapter 4
(4) Basic display mode
The monitor displays basic parameters. (The monitor display is the factory setting.)
The following table lists the parameters that can be displayed in basic display mode:
No.
Code displayed
1
d001 to d104
2
F001
3
F002
4
F003
5
F004
6
A001
7
A002
8
A003
9
A004
10
A005
11
A020
12
A021
13
A022
14
A023
15
A044
16
A045
17
A085
18
b001
19
b002
20
b008
21
b011
22
b037
23
b083
24
b084
25
b130
26
b131
27
C021
28
C022
29
C036
4.2.85 Initial-screen selection (selection of the initial screen to be displayed after power-on)
The initial-screen selection function allows you to specify the screen that is
displayed on the digital operator immediately after the inverter power is turned
on. The table below lists the screens (items) selectable. (The factory setting is
"01" [d001].)
To adjust the screen selection setting of your SJ700 series inverter to an SJ300 series inverter, select "00" (the screen
displayed when the STOP/RESET key was last pressed).
In case Automatic return to inirial display function is enabling, the monitor automatically displays the data selected
initial-screen selection without operating for 10 minutes.
Item

Initial-screen selection

Automatic return to
initial display
Note: When "000" (the screen displayed when the STR key was last pressed) has been selected, the monitor displays
code "*---" (entry to a group of functions) if the functional item displayed last is not "d***" or "F***".
(Example)
If the inverter power is turned off immediately after the setting of "A020" has been changed, the
monitor will display "A---" as the initial screen after the next power-on.
Monitoring indication
Output frequency setting
Acceleration (1) time setting
Deceleration (1) time setting
Keypad Run key routing
Frequency source setting
Run command source setting
Base frequency setting
Maximum frequency setting
[AT] selection
Multispeed frequency setting
Multispeed 1 setting
Multispeed 2 setting
Multispeed 3 setting
V/F characteristic curve selection, 1st motor
V/f gain setting
Operation mode selection
Selection of restart mode
Allowable under-voltage power failure time
Selection of retry after trip
Retry wait time after trip
Function code display restriction
Carrier frequency setting
Initialization mode (parameters or trip history)
Overvoltage suppression enable
Overvoltage suppression level
Terminal [11] function
Terminal [12] function
Alarm relay active state
Function code
Data
000
b038
001 to 060
201
b164
Item
Screen displayed when the STR key was pressed last
(equivalent to the setting on SJ300)
Diplay data for the corresponding d001 to d060.
F001 (output current monitoring)
00
Disabling
01
Enabling(automatically transferring)
4-78
Explanation of Functions
Related code
b038: Initial-screen selection
Description

Advertisement

Table of Contents
loading

Table of Contents