7.1 Specifications
(CT : Constant torque mode, VT : Variable torque mode)
(1) Specifications of the 200 V class model
Model name (type name)
004
SJ700D-***LFEF3/FUF3
Max. applicable motor
CT
0.4
capacity (4-pole) (kW)
VT
0.75
CT
1.0
200V
Rated capacity
VT
1.2
(kVA)
CT
1.2
240V
VT
1.5
Rated input AC voltage
Rated output voltage
Rated output current
CT
3.0
(A)
VT
3.7
Regenerative braking
Minimum connectable
50
resistance ()
Approx. weight (kg)
3.5
(2) Specifications of the 400 V class model
Model name (type name)
007 015 022
SJ700D-***HFEF3/FUF3
Max. applicable
CT
0.75 1.5
motor capacity
(4-pole) (kW)
VT
1.5 2.2
CT
1.7 2.6
400V
Rated
VT
2.1 3.3
capacity
CT
2.0 3.1
(kVA)
480V
VT
2.5 3.9
Rated input AC voltage
Rated output voltage
Rated output
CT
2.5 3.8
current (A)
VT
3.1 4.8
Regenerative braking
Minimum connectable
100 100 100
resistance ()
Approx. weight (kg)
3.5 3.5
(3) Common specifications of 200 V class and 400 V class models
Model name (type name)
004
L
SJ700D-****FEF3/FUF3
Protective structure
Control system
Sine-wave PWM control
Output frequency range
0.1 to 400 Hz (Note 3)
Within ±0.01% of the maximum output frequency for digital input,
Frequency accuracy
within ±0.2% of maximum frequency for digital input (at 25±10C)
Digital input: 0.01 Hz
Frequency setting
Analog input: Maximum output frequency/4000
resolution
IM : V/f characteristic variable with the base frequency set between 30 to 400 Hz,
Voltage/frequency
characteristic
Speed fluctuation
±0.5% (with sensorless vector control) Note8)
CT : 150%/60sec, 200%/3sec
Rated overload current
VT : 120%/60sec, 150%/5sec
Acceleration/deceleration
0.01 to 3,600.0 seconds (in linear or curved pattern)
time
CT : 200%/0.3Hz
SLV
VT : 150%/0.5Hz
Starting
torque
CT : 150%/0Hz range (with motor less one power level than inverter)
0Hz-SLV
VT : Disable.
note) There are only 037HFF3, 040HFEF3 and 040HFUF3 as 037/040 model.
note) There are only 1320HFF3, 1320HFEF3 and 1500HFUF3 as 1320/1500 model.
007
015
022
037
0.75
1.5
2.2
3.7
1.5
2.2
3.7
5.5
1.7
2.5
3.6
5.7
2.1
3.2
4.1
6.7
2.0
3.1
4.3
6.8
2.6
3.9
4.9
8.1
Three-phase (3-wire), 200 to 240 V (+10%, -15%), 50/60 Hz (±5%)
Three-phase (3-wire), 200 to 240 V (corresponding to the input voltage)
5.0
7.5
10.5
16.5
6.3
9.4
12
19.6
Internal BRD circuit (external discharge resistor)
50
35
35
35
3.5
3.5
3.5
3.5
037
055
075
040
3.7
2.2
5.5
7.5
4.0
3.7
5.5
7.5
11
3.6
6.2
9.7
13.1 17.3 22.1 26.3 33.2 40.1 51.9 62.3 76.2 103.2 121.9 150.3 180.1
4.6
7.6
11.0 15.2 20.0 25.6 29.7 39.4 48.4 58.8 72.7 93.5 110.8 135 159.3 200.9
4.3
7.4
11.6 15.8 20.7 26.6 31.5 39.9 48.2 62.3 74.8 91.4 123.8 146.3 180.4 216.1
5.5
9.2
13.3 18.2 24.1 30.7 35.7 47.3 58.1 70.6 87.2 112.2 133 162.1 191.2 241.1
Three-phase (3-wire), 380 to 480 V (+10%, -15%), 50/60 Hz (±5%)
Three-phase (3-wire), 380 to 480 V (corresponding to the input voltage)
5.3
9.0
14
19
6.7
11.1
16
22
Internal BRD circuit
(external discharge resistor)
70
70
35
3.5
3.5
6
6
037
007
015
022
055
075
110
040
L/H
L/H
L/H
L/H
L/H
L/H
L/H
(O terminal input: 12 bits/0 to +10 V, O2 terminal input: 12 bits/-10 to +10 V,
OI terminal input: 12 bits/0 to +20 mA)
constant- or reduced-torque V/f control, SLV : sensorless vector control,
0Hz-SLV : 0Hz ranged sensorless vector control (only CT), vector with sensor (only CT)
055
075
110
150
5.5
7.5
11
15
18.5
7.5
11
15
18.5
8.3
11.0
15.9
22.1
26.3
10.3
15.2
20.0
25.2
29.4
9.9
13.3
19.1
26.6
31.5
12.4
18.2
24.1
30.3
35.3
24
32
46
64
30
44
58
73
16
10
10
7.5
6
6
6
14
110
150
185
220
300
11
15
18.5
22
30
15
18.5
22
30
37
25
32
38
48
58
29
37
43
57
70
35
24
24
20
6
14
14
14
22
150
185
220
300
370
L/H
L/H
L/H
L/H
L/H
IP20
7-1
Specifications
185
220
300
370
450
22
30
37
22
30
37
45
32.9
41.9
50.2
63.0
39.1
48.4
58.5
72.7
39.4
50.2
60.2
75.6
46.9
58.1
70.2
87.2
76
95
121
145
85
113
140
169
External regenerative
braking unit
7.5
5
-
14
14
22
30
370
450
550
750
900 1100
37
45
55
75
90
45
55
75
90
110
75
91
112
149
176
85
105
135
160
195
External regenerative braking unit
-
30
30
30
55
55
450
550
750
900
1100
L/H
L/H
L/H
H
IP00
CT:150%/60sec,
180%/3sec
VT:120%/60sec,
150%/5sec
CT : 180%/0.3Hz
VT : 120%/0.5Hz
CT : 130% (same as the left)
VT : Disable.
550
45
55
55
75
76.2
93.5
91.4
112.2
182
220
210
270
30
43
1320
1500
132
110
150
132
160
217
260
230
290
70
70
1320
1500
H
H

Advertisement