Hitachi SJ700D-004L Instruction Manual page 224

Sj700d-3 series
Hide thumbs Also See for SJ700D-004L:
Table of Contents

Advertisement

Chapter 4
Register No.
Function name
1354h
(Reserved)
1355h
Start frequency adjustment
1356h
Carrier frequency setting
Initialization mode (parameters or
1357h
trip history)
1358h
Country code for initialization
1359h
Frequency scaling conversion factor
135Ah
STOP key enable
135Bh
Restart mode after FRS
135Ch
(Reserved)
135Dh
Dynamic braking usage ratio
135Eh
Stop mode selection
135Fh
Cooling fan control
1360h
(Reserved)
1361h
(Reserved)
1362h
Dynamic braking control
1363h
Dynamic braking activation level
1364h
(Reserved)
Thermistor for thermal protection
1365h
control
1366h
Thermal protection level setting
1367h
Free-setting V/f frequency (1)
1368h
Free-setting V/f voltage (1)
1369h
Free-setting V/f frequency (2)
136Ah
Free-setting V/f voltage (2)
136Bh
Free-setting V/f frequency (3)
136Ch
Free-setting V/f voltage (3)
136Dh
Free-setting V/f frequency (4)
136Eh
Free-setting V/f voltage (4)
136Fh
Free-setting V/f frequency (5)
1370h
Free-setting V/f voltage (5)
1371h
Free-setting V/f frequency (6)
1372h
Free-setting V/f voltage (6)
1373h
Free-setting V/f frequency (7)
1374h
Free-setting V/f voltage (7)
1375h to
(Reserved)
137Ah
137Bh
Brake Control Enable
137Ch
Brake Wait Time for Release
137Dh
Brake Wait Time for Acceleration
137Eh
Brake Wait Time for Stopping
137Fh
Brake Wait Time for Confirmation
1380h
Brake Release Frequency Setting
1381h
Brake Release Current Setting
1382h
Braking frequency
1383h
(Reserved)
1384h
(Reserved)
1385h
Overvoltage suppression enable
1386h
Overvoltage suppression level
Acceleration and deceleration rate
1387h
at overvoltage suppression
Overvoltage suppression
1388h
propotional gain
Overvoltage suppression Integral
1389h
time
138Ah to
(Reserved)
138Fh
(Note) <>indicate the setting range of 75 to 150kW
Function code
R/W
Monitoring and setting items Data resolution
-
-
Inaccessible
b082
R/W 10 to 999
b083
R/W 5 to 150 <5 to 120>(CT), 5 to 120 <5 to 80>(VT)
00 (disabled), 01 (clearing the trip history), 02 (initializing the
data),03 (clearing the trip history and initializing the data),
b084
R/W
04 (clearing the trip history and initializing the data and EzSQ
program)
b085
R/W 0 (Japan), 1 (EU), 2 (U.S.A.)
b086
R/W 1 to 999
b087
R/W 0 (enabling), 1 (disabling), 2 (disabling only stop)
0 (starting with 0 Hz), 1 (starting with matching
b088
R/W
frequency), 2 (starting with active matching frequency)
-
-
Inaccessible
b090
R/W 0 to 1000
b091
R/W 0 (deceleration until stop), 1 (free-run stop)
0 (always operating the fan), 1 (operating the fan only
b092
R/W
during inverter operation [including 5 minutes after
power-on and power-off])
-
-
Inaccessible
-
-
Inaccessible
0 (disabling), 1 (enabling [disabling while the motor is
b095
R/W
stopped]), 2 (enabling [enabling also while the motor is
stopped])
b096
R/W 330 to 380, 660 to 760
-
-
Inaccessible
0 (disabling the thermistor), 1 (enabling the thermistor
b098
R/W
with PTC), 2 (enabling the thermistor with NTC)
b099
R/W 0. to 9999.
b100
R/W 0. to "free-setting V/f frequency (2)"
b101
R/W 0. to 8000
b102
R/W 0. to "free-setting V/f frequency (3)"
b103
R/W 0. to 8000
b104
R/W 0. to "free-setting V/f frequency (4)"
b105
R/W 0. to 8000
b106
R/W 0. to "free-setting V/f frequency (5)"
b107
R/W 0. to 8000
b108
R/W 0. to "free-setting V/f frequency (6)"
b109
R/W 0. to 8000
b110
R/W 0. to "free-setting V/f frequency (7)"
b111
R/W 0. to 8000
b112
R/W 0. to 400.
b113
R/W 0. to 8000
-
-
Inaccessible
b120
R/W 0 (disabling), 1 (enabling) (Only CT)
b121
R/W 0 to 500
b122
R/W 0 to 500
b123
R/W 0 to 500
b124
R/W 0 to 500
b125
R/W 0 to 40000
b126
R/W 0 to 2000 <0 to 1800>
b127
R/W 0 to 40000
-
-
Inaccessible
-
-
Inaccessible
0 (disabling), 1 (enabling), 2 (enabling with
b130
R/W
acceleration), 3(enabling with acceleration during
constant speed and deceleration)
200 V class: 330 to 390 (V)
b131
R/W
400 V class: 660 to 780 (V)
b132
R/W 10 to 3000
b133
R/W 0 to 255
b134
R/W 0 to 65535
-
-
Inaccessible
4-153
Explanation of Functions
Data
resolution
-
0.01 [Hz]
0.1 [kHz]
-
-
0.1
-
-
-
0.1 [%]
-
-
-
-
-
1. [V]
-
-
1. [Ω]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
-
-
0.01 [sec.]
0.01 [sec.]
0.01 [sec.]
0.01 [sec.]
0.01 [Hz]
0.1 [%]
0.01 [Hz]
-
-
-
1 [V]
0.01 [sec.]
0.01
0.001 [sec.]
-