Hitachi SJ700D-004L Instruction Manual page 276

Sj700d-3 series
Hide thumbs Also See for SJ700D-004L:
Table of Contents

Advertisement

Chapter 8
Code
Function name
Low-current indication signal
C038
output mode selection
Low-current indication signal
C039
detection level
C040
Overload signal output mode
C041
Overload level setting
C042
Frequency arrival setting for accel.
C043
Frequency arrival setting for decel.
C044
PID deviation level setting
Frequency arrival setting for
C045
acceleration (2)
Frequency arrival setting for
C046
deceleration (2)
C052
Maximum PID feedback data
C053
Minimum PID feedback data
Over-torque (forward-driving) level
C055
setting
Over-torque (reverse regenerating)
C056
level setting
Over-torque (reverse driving) level
C057
setting
Over-torque (forward
C058
regenerating) level setting
Electronic thermal warning level
C061
setting
C062
Alarm code output
C063
Zero speed detection level
C064
Heat sink overheat warning level
C071
Communication speed selection
C072
Node allocation
Communication data length
C073
selection
C074
Communication parity selection
C075
Communication stop bit selection
Selection of the operation after
C076
communication error
Communication timeout limit
C077
before tripping
C078
Communication wait time
C079
Communication mode selection
C081
[O] input span calibration
C082
[OI] input span calibration
C083
[O2] input span calibration
C085
Thermistor input tuning
C091
Debug mode enable
C101
Up/Down memory mode selection
C102
Reset mode selection
C103
Restart mode after reset
C105
FM gain adjustment
C106
AM gain adjustment
C107
AMI gain adjustment
C109
AM bias adjustment
C110
AMI bias adjustment
(Note) <>indicate the setting range of 75 to 150kW
(Note) CT : Constant torque mode, VT : variable torque mode, you can set CT or VT by b049.
Monitored data or setting
00 (output during acceleration/deceleration and constant-speed
operation), 01 (output only during constant-speed operation)
0.0 to 2.00 x "rated current" (A)
<0.0 to 1.80 x "rated current" (A) > (In case of CT)
0.0 to 1.50 x "rated current" (A) (In case of VT)
00 (output during acceleration/deceleration and constant-speed
operation), 01 (output only during constant-speed operation)
0.0 to 2.00 x "rated current" (A)
<0.0 to 1.80 x "rated current" (A) > (In case of CT)
0.0 to 1.50 x "rated current" (A) (In case of VT)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.0 to 100.0 (%)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.0 to 100.0 (%)
0.0 to 100.0 (%)
0. to 200. (%) <0. to 180. (%)>
0. to 200. (%) <0. to 180. (%)>
0. to 200. (%) <0. to 180. (%)>
0. to 200. (%) <0. to 180. (%)>
0. to 100. (%)
00 (disabling), 01 (3 bits), 02 (4 bits)
0.00 to 99.99, 100.0 (Hz)
0. to 200.0 (C)
02 (loopback test), 03(2400bps), 04(4800bps),
05(9600bps), 06(19.2kbps), 07(38.4kbps),
08(57.6kbps), 09(76.8kbps), 10(115.2kbps)
1. to 247.
7 (7 bits), 8 (8 bits)
00 (no parity), 01 (even parity), 02 (odd parity)
1 (1 bit), 2 (2 bits)
00 (tripping), 01 (tripping after decelerating and stopping the
motor), 02 (ignoring errors), 03 (stopping the motor after
free-running), 04 (decelerating and stopping the motor)
0.00 to 99.99 (s)
0. to 1000. (ms)
00(ASCII), 01(Modbus-RTU)
0. to 9999., 1000 to 6553(10000 to 65530)
0.0 to 999.9, 1000.
(Do not change this parameter, which is intended for factory
adjustment.)
00 (not storing the frequency data), 01 (storing the frequency data)
00 (resetting the trip when RS is on),
01 (resetting the trip when RS is off),
02 (enabling resetting only upon tripping [resetting when RS is on]),
03(resetting only trip)
00 (starting with 0 Hz), 01 (starting with matching frequency),
02 (restarting with active matching frequency)
50. to 200. (%)
0. to 100. (%)
8-11
List of Data Settings
Change during
Default
RUN operation
Memo
FF
FEF
FUF
b031≠10 b031=10
01
Not
Rated current
Allowed Allowed
01
Not
Rated current
Allowed Allowed
0.00
Not
0.00
Not
3.0
Not
0.00
Not
0.00
Not
100.0
Not
0.0
Not
100.
Not
100.
Not
100.
Not
100.
Not
80.
Not
00
Not
0.00
Not
120.
Not
04
Not
1.
Not
7
Not
00
Not
1
Not
02
Not
0.00
Not
0.
Not
00
Not
Factory setting
Allowed Allowed
Factory setting
Allowed Allowed
Factory setting
Allowed Allowed
Factory setting
Allowed Allowed 4-72
00
Not
00
Not
00
Allowed Allowed
00
Not
100.
Allowed Allowed 4-73
100.
Allowed Allowed
100.
Allowed Allowed
0.
Allowed Allowed
20.
Allowed Allowed
Page
Allowed
4-69
Allowed
4-40
Allowed
4-62
Allowed
Allowed 4-29
Allowed
4-62
Allowed
Allowed
4-29
Allowed
Allowed
Allowed
4-65
Allowed
Allowed
Allowed 4-38
Allowed 4-65
Allowed 4-64
Allowed 4-68
Allowed
Allowed
Allowed
Allowed
4-113
Allowed
Allowed
Allowed
Allowed
Allowed
Not
Allowed 4-56
4-54
Allowed
4-74