Hitachi SJ700D-004L Instruction Manual page 278

Sj700d-3 series
Hide thumbs Also See for SJ700D-004L:
Table of Contents

Advertisement

Chapter 8
Code
Function name
H001
Auto-tuning Setting
H002
Motor data selection, 1st motor
H202
Motor data selection, 2nd motor
H003
Motor capacity, 1st motor
H203
Motor capacity, 2nd motor
H004
Motor poles setting, 1st motor
H204
Motor poles setting, 2nd motor
H005
Motor speed constant, 1st motor
H205
Motor speed constant, 2nd motor
H006
Motor stabilization constant, 1st motor
H206
Motor stabilization constant, 2nd motor
H306
Motor stabilization constant, 3rd motor
H020
Motor constant R1, 1st motor
H220
Motor constant R1, 2nd motor
H221
Motor constant R2, 1st motor
H221
Motor constant R2, 2nd motor
H222
Motor constant L, 1st motor
H222
Motor constant L, 2nd motor
H223
Motor constant Io
H223
Motor constant Io, 2nd motor
H224
Motor constant J
H224
Motor constant J, 2nd motor
H030
Auto constant R1, 1st motor
H230
Auto constant R1, 2nd motor
H231
Auto constant R2, 1st motor
H231
Auto constant R2, 2nd motor
H232
Auto constant L, 1st motor
H232
Auto constant L, 2nd motor
H233
Auto constant Io, 1st motor
H233
Auto constant Io, 2nd motor
H234
Auto constant J, 1st motor
H234
Auto constant J, 2nd motor
H050
PI proportional gain for 1st motor
H250
PI proportional gain for 2nd motor
H051
PI integral gain for 1st motor
H251
PI integral gain for 2nd motor
H052
P proportional gain setting for 1st motor
H252
P proportional gain setting for 2nd motor
H060
Zero LV lmit for 1st motor
H260
Zero LV lmit for 2nd motor
H061
Zero LV starting boost current for 1st motor
H261
Zero LV starting boost current for 2nd motor
H070
Terminal selection PI proportional gain setting
H071
Terminal selection PI integral gain setting
H072
Terminal selection P proportional gain setting
H073
Gain switching time
(Note)<>indicate the setting range of 75 to 150kW
Monitored data or setting
00 (disabling auto-tuning),
01 (auto-tuning without rotation),
02 (auto-tuning with rotation)
00 (Hitachi standard data), 01 (auto-tuned data),
02 (auto-tuned data [with online auto-tuning function])
0.20 to 75.00 (kW) <0.20 to 160. (kW) >
2, 4, 6, 8, 10 (poles)
0.001 to 9.999, 10.00 to 80.00 (10.000 to 80.000)
0. to 255.
0.001 to 9.999, 10.00 to 65.53 ()
0.001 to 9.999, 10.00 to 65.53 ()
0.01 to 99.99, 100.0 to 655.3 (mH)
0.01 to 99.99, 100.0 to 655.3 (A)
0.001 to 9.999, 10.00 to 99.99,
100.0 to 999.9, 1000. to 9999
0.001 to 9.999, 10.00 to 65.53 ()
0.001 to 9.999, 10.00 to 65.53 ()
0.01 to 99.99, 100.0 to 655.3 (mH)
0.01 to 99.99, 100.0 to 655.3 (A)
0.001 to 9.999, 10.00 to 99.99,
100.0 to 999.9, 1000. to 9999.
0.0 to 999.9, 1000.
0.0 to 999.9, 1000.
0.01 to 10.00
0.0 to 100.0
0. to 50. (%)
0.0 to 999.9, 1000.
0.00 to 10.00
0. to 9999. (ms)
8-13
List of Data Settings
Change during
Default
RUN operation
Memo
FF
FEF FUF
b031≠10 b031=10
00
Not
00
Not
00
Not
Factory setting
Not
Factory setting
Not
4
Not
4
Not
1.590
Allowed
1.590
Allowed
100.
Allowed
100.
Allowed
100.
Allowed
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
Factory setting
Not
100.0
Allowed
100.0
Allowed
100.0
Allowed
100.0
Allowed
1.00
Allowed
1.00
Allowed
100.0
Allowed
100.0
Allowed
50.
Allowed
50.
Allowed
100.0
Allowed
100.0
Allowed
1.00
Allowed
100.
Allowed
Page
Not
Not
Not
4-85
Not
Not
Not
Not
4-89
Allowed
4-90
4-97
Allowed
Allowed
Allowed
4-79
Allowed
Not
Not
Not
Not
4-88
Not
4-89
4-90
Not
4-97
Not
Not
Not
Not
Not
Not
Not
Not
4-85
4-88
Not
4-89
Not
4-90
4-97
Not
Not
Not
Not
Allowed
Allowed
Allowed
Allowed
4-58
Allowed
Allowed
Allowed
Allowed
Allowed
4-90
Allowed
Allowed
Allowed
4-58
Allowed
Allowed

Advertisement

Table of Contents
loading

Table of Contents