Chapter 8
IMPORTANT! Please be sure to set the motor nameplate data into appropriate parameters to ensure proper
operation and protection of the motor.
*b012 is the motor overload protection value
*A082 is the motor voltage selection
*H003 is the motor kW capacity
*H004 is the number of motor poles
Please refer to the appropriate pages in this guide and the Instruction Manual for further details.

8.1 Precautions for Data Setting

- FF, FEF and FUF are the parts of inverter model.
For example, in case of 1.5kW/400V class, SJ700D-015H***3
- Even though the inverter is driving the motor, you can change some parameters. If you specify "10" for the
software lock mode selection (b031), you can change some more parameters. See the table below.

8.2 Monitoring Mode

With the default settings, the initial display on the operator after powering on is always the output frequency
monitor (d001). To change the initial display content, change the setting of the initial-screen selection (b038) as
required.
Code
Function name
d001 Output frequency monitoring
d002 Output current monitoring
d003 Rotation direction minitoring
Process variable (PV),
d004
PID feedback monitoring
Intelligent input
d005
terminal status
Intelligent output
d006
terminal status
Scaled output frequency
d007
monitoring
d008 Actual-frequency monitoring
d009 Torque command monitoring
d010 Torque bias monitoring
d012 Torque monitoring
d013 Output voltage monitoring
d014 Power monitoring
d015 Cumulative power monitoring
Cumulative operation RUN time
d016
monitoring
Cumulative power-on time
d017
monitoring
d018 Heat sink temperature monitoring
d019 Motor temperature monitoring
Monitored data or setting
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.0 to 999.9, 1000 to 9999 (A)
F (forward rotation), o (stopped), r (reverse rotation)
0.00 to 99.99, 100.0 to 999.9, 1000. to 9999.
1000 to 9999 (10000 to 99990), 100 to 999 (100000 to 999000)
FW
8
7 6
5 4
3 2
1
AL 15 14 13 12
11
0.00 to 99.99, 100.0 to 999.9, 1000. to 9999., 1000 to 3996 (10000 to 39960)
-400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz)
-200. to +200. (%)
0.0 to 600.0 (V)
0.0 to 999.9 (kW)
0.0 to 999.9, 1000. to 9999.
1000 to 9999 (10000 to 99990), 100 to 999 (100000 to 999000)
0. to 9999., 1000 to 9999 (10000 to 99990),
100 to 999 (100000 to 999000) (hr)
-020. to 200.0 (C)
(*** is described as FF, FEF or FUF.)
(Example)
Terminals FW, 7, 2, and 1: ON
Terminals 8, 6, 5, 4, and 3: OFF
(Example)
Terminals 12 and 11: ON
Terminals AL, 15, 14, and 13: OFF
8-1

List of Data Settings

Change during
Default
RUN operation
FF
FEF FUF b031≠10 b031=10
Allowed Allowed 4-1
Allowed Allowed 4-2
Page
4-1
4-1
4-1
4-2
4-2
4-3
4-3
4-3
4-3
4-3
4-3
4-4
4-4
4-4
4-4
4-4