Hitachi SJ700D-004L Instruction Manual page 277

Sj700d-3 series
Hide thumbs Also See for SJ700D-004L:
Table of Contents

Advertisement

Chapter 8
Code
Function name
C111
Overload setting (2)
C121
[O] input zero calibration
C122
[OI] input zero calibration
C123
[O2] input zero calibration
C130
Output 11 on-delay time
C131
Output 11 off-delay time
C132
Output 12 on-delay time
C133
Output 12 off-delay time
C134
Output 13 on-delay time
C135
Output 13 off-delay time
C136
Output 14 on-delay time
C137
Output 14 off-delay time
C138
Output 15 on-delay time
C139
Output 15 off-delay time
C140
Output RY on-delay time
C141
Output RY off-delay time
C142
Logical output signal 1 selection 1
C143
Logical output signal 1 selection 2
C144
Logical output signal 1 operator selection
C145
Logical output signal 2 selection 1
C146
Logical output signal 2 selection 2
C147
Logical output signal 2 operator selection
C148
Logical output signal 3 selection 1
C149
Logical output signal 3 selection 2
C150
Logical output signal 3 operator selection
C151
Logical output signal 4 selection 1
C152
Logical output signal 4 selection 2
C153
Logical output signal 4 operator selection
C154
Logical output signal 5 selection 1
C155
Logical output signal 5 selection 2
C156
Logical output signal 5 operator selection
C157
Logical output signal 6 selection 1
C158
Logical output signal 6 selection 2
C159
Logical output signal 6 operator selection
C160
Input terminal response time setting 1
C161
Input terminal response time setting 2
C162
Input terminal response time setting 3
C163
Input terminal response time setting 4
C164
Input terminal response time setting 5
C165
Input terminal response time setting 6
C166
Input terminal response time setting 7
C167
Input terminal response time setting 8
C168
Input terminal response time setting FW
C169
Multistage speed/position determination time
(Note)<>indicate the setting range of 75 to 150kW
Monitored data or setting
0.0 to 2.00 x "rated current" (A)
<0.0 to 1.80 x "rated current" (A) > (In case of CT)
0.0 to 1.50 x "rated current" (A) (In case of VT)
0. to 9999., 1000 to 6553 (10000 to 65530)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
0. to 200. ( 2ms)
0. to 200. ( 2ms)
0. to 200. ( 2ms)
0. to 200. ( 2ms)
0. to 200. ( 2ms)
0. to 200. ( 2ms)
0. to 200. ( 2ms)
0. to 200. ( 2ms)
0. to 200. ( 2ms)
0. to 200. ( 10ms)
8-12
List of Data Settings
Change during
Default
RUN operation
Memo
FF
FEF FUF
b031≠10 b031=10
Rated current
Allowed Allowed 4-40
Factory setting
Allowed Allowed
Factory setting
Allowed Allowed
Factory setting
Allowed Allowed
0.0
Not
0.0
Not
0.0
Not
0.0
Not
0.0
Not
0.0
Not
0.0
Not
0.0
Not
0.0
Not
0.0
Not
0.0
Not
0.0
Not
00
Not
00
Not
00
Not
00
Not
00
Not
00
Not
00
Not
00
Not
00
Not
00
Not
00
Not
00
Not
00
Not
00
Not
00
Not
00
Not
00
Not
00
Not
1.
Not
1.
Not
1.
Not
1.
Not
1.
Not
1.
Not
1.
Not
1.
Not
1.
Not
0.
Not
Page
-
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
4-72
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
4-66
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
4-72
Allowed
Allowed
Allowed
Allowed
4-48
Allowed
4-108

Advertisement

Table of Contents
loading

Table of Contents