1. INTRODUCTION

1. INTRODUCTION
This user's manual describes specifications, handling, and programming of the
AJ65BT-D62/ D62D/ D62D-S1 high-speed counter modules (hereafter abbreviated as
high-speed counter module) to be used in a CC-Link system.
The high-speed counter module can import and count pulses of a pulse generator
which cannot be imported by a programmable controller CPU.
The high-speed counter module can detect and count up to 400,000 pulses per
second.
The high-speed counter module is available in the following three different types.
Item
Type
Preset
External
input
Function start
Max. counting speed
CC-Link station type
Counting range
Counting switch-over
The high-speed counter module counts 1-phase and 2-phase pulse inputs as
described below.
1-phase pulse input multiplied by one ............ Counts on the leading edge or trailing
1-phase pulse input multiplied by two ............ Counts on the leading edge and trailing
2-phase pulse input multiplied by one ............ Counts on the leading edge or trailing
2-phase pulse input multiplied by two ........... Counts on the leading edge and trailing
2-phase pulse input multiplied by four ............ Counts on the leading edge and trailing
AJ65BT-D62
DC input
sink output type
5/12/24VDC 2 to 15mA
Max. 200kPPS
Remote device station
24-bit binary (0 to 16777215)
200k/10k
edge of a pulse.
edge of a pulse.
edge of a phase A pulse.
edge of a phase A pulse.
edge of phase A and phase B pulses.
1 - 1
MELSEC-A
AJ65BT-D62D
AJ65BT-D62D-S1
Differential input sink output type
Differential input
5/12/24VDC
Max. 400kPPS
1 phase: 400k
/10k
2 phases: 300k
2 to 5mA