DETAILED SECTION DESCRIPTIONS

SYSTEM FEATURES

2.3. SYSTEM FEATURES
2.3.1. Power Saver Modes
1. Going into a Power Saver Mode
- Power Saver Timer -
When the power saver timer expires, the machine automatically goes into a
Power Saver Mode. During the power saver mode, the fusing lamp is turned
off or on according to the User Switch 05, bit 6 setting. All the LEDs on the op-
eration panel are turned off and "SAVING ENERGY" is displayed on the LCD.
The CPU is not turned off during the power saver mode.
The machine returns to the standby mode in the following conditions:
When the document sensor is activated.
When any key on the operation panel is pressed.
When the handset goes off-hook.
Cross Reference
Power saver timer initial setting: System Switch 0B, bits 2 and 3
(1 minute, 3 minutes, 5 minutes, or Unlimited: Timer disabled)
- Turning the Fusing Lamp On or Off -
The machine will not turn off the fusing lamp if one of the following conditions
exists.
Mechanical error(s)
Service call error(s)
It takes approximately 50 s to reach the printing temperature from room tem-
perature after the machine turns on the fusing lamp. To avoid any
communication error from memory overflow, the machine will not turn off the
fusing lamp in the following conditions.
If the remaining SAF memory is less than 64 kbytes.
Within 30 minutes after a communication error occurs.