Ricoh infotec 3671F Service Manual page 131

Table of Contents

Advertisement

July 30th, 1996
16th byte to 35th byte - Remote terminal's ID (RTI, TSI or CSI) (ASCII)
36th byte - Communication mode #1
Bits 0 - 1: Resolution used
=  
: Standard ,  
Bit 0
1
Bit 1
0
Bit 2: Not used
Bit 3: ECM
Bits 4 to 7: Communication mode used
Bit 4
0
Bit 5
0
=
: Normal
Bit
6
0
0
Bit 7
Bit 4
0
Bit 5
0
=
: Forwarding
Bit
6
1
Bit 7
0
37th byte - Communication mode #2
Bit 0: Tx or Rx
Bit 1: Reduction in Tx
Bit 2: Batch transmission
Bit 3: Send later transmission
Bit 4: Transmission from
Bits 5 to 7: Not used
38th byte - Number of errors during communication (Hex)
39th to 41st byte - 1st error code and page number where the error occurred
42th to 44th byte - 2nd error code and page number where the error occurred
45th to 47th byte - 3rd error code and page number where the error occurred
48th to 50th byte - 4th error code and page number where the error occurred
51st to 53rd byte - 5th error code and page number where the error occurred
F80006 to F8000E(H) - ROM part number and suffix (ASCII)
: Detail ,  
0
1
: Fine
1
1
1
0
0
1
: Confidential
0
0
0
0
1
0
Automatic
:
Service Call
1
0
39th byte - Page number where the error occurred (Hex)
40th byte - Error code (low - BCD)
41st byte - Error code (high - BCD)
4-79
SERVICE TABLES AND PROCEDURES
SERVICE RAM ADDRESSES
0: Off, 1: On
1
1
: Polling
: Transfer
0
0
0: Tx, 1: Rx
0: Not reduced, 1: Reduced
0: Not used, 1: Used
0: Not used, 1: Used
0: ADF, 1: Memory