July 30th, 1996
3. Skew
Possible Cause:
An incorrect type or size of document is used.
The document guide is not properly set.
The operation panel is not properly closed.
The scanner rollers (pick-up and feed rollers) are dirty.
Obstruction in the document paper path.
Action:
1. Check that a correct type of document is being used.
2. Check that the operation panel is securely closed and also check that the
document guide is properly set.
3. Check for obstructions in the paper path.
4. If the problem still remains, do the following.
Clean the rollers with a soft cloth and water, and replace them if they
are damaged.
4. Multi-feed
Action:
Clean or replace the separation pad.
MECHANICAL PROBLEMS
7-15